MedPath

Development of Magnetic Resonance Spectroscopic Imaging Techniques for Imaging Metabolites in Human Brain and Muscle

Not Applicable
Recruiting
Conditions
Brain Mapping
Healthy Volunteer
Interventions
Other: NSR MAGNETOM 7T
Other: 1Tx x 32Rx Head Coil
Registration Number
NCT01266577
Lead Sponsor
National Institute of Mental Health (NIMH)
Brief Summary

Background:

- Magnetic resonance imaging (MRI) is a widely used scanning technique to obtain images of the human body and evaluate activity in the brain. A particular MRI method called magnetic resonance spectroscopy (MRS) can be used to study brain chemistry as well, which may help researchers who are studying new treatments for psychiatric illnesses. Researchers are interested in improving current MRI and MRS techniques, as well as developing new MRI and MRS techniques to view and measure brain chemicals and brain activity.

Objectives:

- To implement, develop, and optimize brain chemistry imaging techniques using magnetic resonance imaging and magnetic resonance spectroscopy.

Eligibility:

- Healthy individuals between 18 and 65 years of age.

Design:

* This study will involve a screening visit and a scanning visit at the National Institutes of Health Clinical Center.

* Participants will be screened with a full medical and physical examination, blood and urine tests, and neurological testing.

* During the second visit, participants will have an MRI scan of the brain. (Participants who have received an MRI within the past year will not need to have a second one; the images of the previous scan will be used for this study.) All participants will then have an MRS scan using the same scanning equipment.

Detailed Description

Magnetic resonance spectroscopy (MRS) is identical to MRI except that the metabolite signal, rather than the dominant water signal, is measured. Proton (1H) MRS and phosphorous (P) MRS are two powerful spectroscopy methods to measure metabolism in vivo.

By using water suppression techniques, proton MRS can monitor levels of important brain metabolites and neurotransmitters such as N-acetylaspartate (NAA), creatine, choline, lactate, myo-inositol, glutamate, glutamine, gamma aminobutyric acid (GABA), and glutathione.

P MRS can be utilized to measure energy phosphate metabolites of inorganic phosphate (Pi), phosphocreatine (PCr), adenosine diphosphate (ADP), and adenosine triphosphate (ATP) in brain and muscle. In addition, phosphocholine (PC), phosphoethanolamine (PE), glycerophosphocholine (GPC) and glyceophosphoethanolamine (GPE) can also be detected in brain tissues.\<TAB\>

This protocol proposes three main goals. First, to implement and optimize current proton and P MRS methods published in the literature for the imaging of metabolites in human brain and muscle. Second, to further develop new methods for use in similar brain and muscle MRS applications. Third, to exchange MRS data with other studies in order to provide data analysis and quality control for the studies under this, other NIH, or outside protocols.

To develop and optimize in vivo MRS methods, 300 healthy volunteers will be recruited over a period of ten years. The subjects will be aged 18-65 years, and include representative numbers of males, females, and minorities.

The experiments will be performed on the GE 3T, Siemens 3T and 7T MRI scanners located at the NIH In Vivo NMR Research Center. In the first portion of the study, a clinical MRI will be performed to ensure the subject has no abnormal brain conditions. In the second portion of the study, MRS scans will be performed in various system and pulse parameter combinations. No medications will be involved. Total scan time during the MRS scan will be one to two hours long.

We expect to obtain high quality proton and/or phosphorous spectroscopy imaging from healthy volunteers that will help establish accurate and reliable spectroscopy methods for clinical investigators to perform non-invasive studies of psychiatric, neurological disorders, and other diseases in human brain or muscle.

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
300
Inclusion Criteria

Not provided

Exclusion Criteria

Not provided

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
One Arm1Tx x 32Rx Head CoilSubjects receive the same scan
One ArmNSR MAGNETOM 7TSubjects receive the same scan
Primary Outcome Measures
NameTimeMethod
The primary outcome is the quality of the MR spectroscopy which includes spectrum signal-to-noise (SNR) ratio, spectral lineshape, linewidth, and resolution.prospective and ongoing

to obtain more accurate and reliable MRS data from the human brain and muscle

Secondary Outcome Measures
NameTimeMethod
The secondary outcome is the performance improvements of the scanner hardware, software and methodology.prospective and ongoing

to obtain more accurate and reliable MRS data from the human brain and muscle

Trial Locations

Locations (1)

National Institutes of Health Clinical Center

🇺🇸

Bethesda, Maryland, United States

© Copyright 2025. All Rights Reserved by MedPath