Comparison of Contrast Agent Administration Protocols
- Conditions
- Radiography, Thoracic
- Interventions
- Diagnostic Test: Body/weight adaptionDiagnostic Test: Standard dose
- Registration Number
- NCT04300972
- Lead Sponsor
- Oslo University Hospital
- Brief Summary
The will compare two different ways of administering contrast media in CT exams of the chest:
1. a fixed dose of contrast medium
2. a weight- and body-type-adapted dose of contrast medium
The goal is to see if one protocol is superior to the other in reliably producing diagnostic CT images.
- Detailed Description
The continuing advances in computed tomographic (CT) technology in the past decades have provided ongoing opportunities to improve CT image quality, clinical practice and discover new clinical CT imaging applications. New CT technology, however, has introduced new challenges in clinical radiology practice. One of the challenges deals with intravenous contrast medium (CM) administration. Although multidetector CT allows more efficient and flexible use of contrast medium than single-detector CT, to fully reap the benefits of multidetector CT, certain technical challenges involving maximum contrast enhancement and optimal contrast material delivery must be met (1). While CT technology has evolved, the practice of CT intravenous CM administration has been continually debated and updated. The users of new CT technology, accompanied with its newly added technical complexity, discover they fall short of achieving a desired image quality with the traditional standard administration of CM. This entails a change in practice. In the department of Radiology at St Olav University Hospital (SOH), a new protocol for CM administration is now developed and is ready for implementation. This protocol is based on a body weight adapted CM administration, while the current protocol has a fixed CM injection. In this study, this newly CM administration protocol for thoracic CT will be compared to the fixed CM injection protocol. To our knowledge, very few studies (2) have been published on the use of body weight adapted injection protocols for Thoracic CT. Most of the studies report the impact of body weight adapted CM injection protocols for the coronary arteries of CT angiography (3- 5). Therefore, the aim of this study is to determine whether individually tailored protocol(s) for the injection of CM results in higher and more homogeneous vascular attenuation at thoracic CT compared with conventional injection protocols using fixed injection parameters. We know that to achieve optimal contrast enhancement in thoracic CT involves essential factors such as CT tube voltage and CT attenuation, patient factors, CM factors and CT scanning factors (1) and thus all these factors will be addressed and discussed in this investigation.
Specific aims of the study:
1. To assess and compare the CT attenuation achieved with both protocols
2. Compare the required amount of CM using weight adapted CM protocol and fixed CM injection protocol
3. Compare the quality of the images using weight adapted CM protocol and fixed CM injection protocol
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 67
Not provided
Not provided
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description weight and body type adapted dose Body/weight adaption - fixed dose Standard dose -
- Primary Outcome Measures
Name Time Method CT density of large vessel, measured in Hounsfield units (HU) in the imaging software (PACS) immediately after imaging
- Secondary Outcome Measures
Name Time Method