跳至主要内容
临床试验/NCT05632016
NCT05632016招募中不适用

The Impact of Erector Spinae Block (ESP)on Neurophysiological Monitoring in Patients Undergoing Scoliosis Repair Under TIVA

Ain Shams University1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2022年10月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
40
试验地点
1
主要终点
The effect of ESP on neurophysiological monitoring

研究概览

简要总结

Scoliosis surgery requires intraoperative neuromonitoring. Electrophysiological monitors used include somatosensory evoked potentials (SEPS) and motor-evoked potentials (MEPS). MEPS are a measured muscular contraction produced by stimulation of the motor cortex via electrodes to the scalp. Evoked electromyography (EMG) of pedicle screws allows for evaluation of potential injury from incorrect screw placement. Anaesthetic agents: Volatile agents produce dose-related decreases in amplitude of MEPs. MEPs are also stopped with the use of neuromuscular blockade (NMB). It is accepted that an initial dose of a NMB agent will be metabolised before monitoring is required. Therefore a TIVA technique is the recommended anaesthetic technique for this procedure. Propofol has been shown to attenuate MEP signals and should be kept in mind. This effect can be mitigated with the use of Ketamine which increases SEP and MEP amplitudes. Benzodiazepines as well as opioids (including intrathecal opioids) have been shown to have minimal effect on signals. α2 agonists attenuate MEP amplitudes (3).

Accordingly, the goals of spine correction surgery include hemodynamic stability with no interference in neuromonitoring and optimal pain control. Multimodal analgesia is recommended in the preoperative intraoperative and postoperative periods. Intrathecal morphine has been shown to reduce pain scores and allow for improved postoperative analgesia. Remifentanil infusions are used to reduce propofol requirements thus improving neuromonitoring. Hyperalgesia has been noted but various strategies can be used to mitigate this. Intravenous lignocaine and ketamine have been shown to reduce opioid requirements. The use of α2 agonists help to reduce opioid requirements but can attenuate neuromonitoring signals.

Postoperative administration of extensive amounts of opioids can cause well known side-effects, such as respiratory depression, sedation, pruritis, nausea, vomiting, and constipation. Ileus is also a common complication due to the nature of the surgery and opioid use in the perioperative period. Even with opioids, pain is not always sufficiently managed. Inadequate pain control increases cardiac and respiratory complications, delays mobilization, increases the length of hospital stay and may increase the risk of developing a chronic pain syndrome . The above mentioned complications indicate the need for a novel regional anesthesia techniques. Until recently, regional anesthesia techniques have not been used on a regular basis in spine surgery as an immediate postoperative neurological examination is required. This examination of the motor and sensory function of the spinal cord eliminates spinal and epidural analgesia as suitable pain treatments. Novel interfascial plane blocks, such as the erector spinae plane (ESP) block, generate regional analgesia without interference of spinal cord function and are therefore suitable for spinal surgery pain management .

An ESP block has a very low risk of complications, as sonoanatomy is easily recognizable and there are no structures in close proximity at risk of needle injury. The transverse process acts as an anatomical barrier and avoids needle insertion into the pleura or vessels, thus preventing a pneumothorax or hematoma. Moreover, the needle is relatively far from the vertebral canal, which means the risk of spinal cord injury is very low. It is applied preoperatively before skin incision as a preemptive analgesia so it suppresses chronic sensitization process. In addition, it may abolish the neuroendocrine stress response by decreasing release of the counterregulatory hormones like catecholamines the mechanism by which it may augment controlled hypotensive anaesthesia

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Other
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
12 Years 至 25 Years(Child, Adult)
性别
All
接受健康志愿者

入选标准

  • patients with American Association of Anesthesiologists up to III physical status undergoing scoliosis repair under TIVA.

排除标准

  • Patients with an ASA status above III.
  • patient or guardian refusal to participate, patients with multiple congenital anomalies.
  • hypersensitivity or contraindication to the study drugs.
  • severe restrictive pulmonary disease indicating postoperative ventilation.

结局指标

主要结局

The effect of ESP on neurophysiological monitoring

时间窗: the whole intraoperative time

the effect of ESP on SSEPs and MEPs during scoliosis repair

次要结局

  • Intra and postoperative analgesic effect of ESP(24 hours)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验