Neurolens and Contact Lens Discomfort
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 30
- 试验地点
- 2
- 主要终点
- Change in Contact Lens Discomfort
研究概览
简要总结
The objective of this study is to determine how neurolens® influences contact lens discomfort in uncomfortable myopic soft contact lenses wearers. It is hypothesized that uncomfortable soft contact lens wearers are experiencing some level of discomfort associated with increased vergence demand when looking at near targets and will experience discomfort relief when wearing neurolens® over their habitual soft contact lenses. Uncomfortable, myopic soft contact lens wearers will be recruited. Each participant will be masked and randomly assigned a placebo pair of spectacles or a neurolens® spectacle pair for approximately one month. A prospective, randomized clinical trial will be performed. Participants and investigators will be masked to the treatment.
详细描述
Discomfort is the primary reason for contact lens dissatisfaction and discontinuation. Symptoms of contact lens discomfort are often attributed to dryness; however, severity of dry eye and discomfort symptoms is not correlated with clinical dry eye severity. When clinical signs of contact lens discomfort and dryness misalign with symptom severity, the possibility of an under-recognized etiology must be considered.
Symptoms associated with contact lens discomfort are similar to symptoms reported with binocular vision disorders and accommodative and vergence strain. Eyestrain, fatigue, and increased/more frequent end-of-day symptoms are noted by patients in both groups of conditions. It has been reported that uncomfortable contact lens wearers have an unusually high prevalence of binocular vision disorders and clinical signs. Basic optical calculations show that myopes must converge and accommodate more when corrected with contact lenses versus spectacles, so it is reasonable to hypothesize that a myopic contact lens wearer may experience eyestrain and discomfort associated with vergence fatigue while wearing contact lenses, but not while wearing single vision spectacles.
neurolens® is a type of spectacle lens that uses contoured prism to alleviate vergence demands and fatigue at near and, therefore, encourages comfortable vision. This spectacle design uses the neurolens® Measurement Device (nMD) to measure eye alignment and determine the spectacle lenses that are uniquely designed for each wearer. Acknowledging that some amount of contact lens discomfort may be caused by vergence fatigue, it is possible that uncomfortable contact lens wearers who wear neurolens® over their contact lenses will achieve discomfort relief.
The objective of this study is to determine how neurolens® influences contact lens discomfort in uncomfortable myopic soft contact lenses wearers. Investigators hypothesize that uncomfortable soft contact lens wearers are experiencing some level of discomfort associated with increased vergence demand when looking at near targets and will experience discomfort relief when wearing neurolens® over their habitual soft contact lenses. Uncomfortable, myopic soft contact lens wearers will be recruited. Each participant will be masked and randomly assigned a placebo pair of spectacles or a neurolens® spectacle pair for approximately one month. A prospective, randomized clinical trial will be performed. Participants and investigators will be masked to the treatment.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Double (Participant, Investigator)
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Uncomfortable soft contact lens wearers (CLDEQ-8 ≥ 17 points)
- •Adult, pre-presbyopic age range (18 - 35 years)
- •Visual acuity of 20/25 or better in each eye with habitual contact lenses
- •Soft, spherical or low toric, single vision soft contact lens wearer:
- •Habitual contact lens sphere power -0.75 D or more myopic
- •Habitual contact lens are spherical design or have 1.75 D or less of cylinder correction
- •Habitual soft contact lenses are single vision design
- •Valid contact lens prescription at the date of the baseline
- •No significant subjective over-refraction in either eye with habitual soft contact lenses
- •No significant subjective over-refraction in either eye with habitual soft contact lenses
- •Sphere: ≤ 0.50 D myopia, ≤ 0.50 D hyperopia
- •Cylinder: ≤ 0.75 D
- •Valid measurement on the neurolens® Measurement Device (nMD2)
- •A numerical neurolens value
- •No low Measurement Quality Index (MQI) < 0.8 or convergence excess
排除标准
- •History of ocular surgery
- •History of ocular disease, amblyopia, strabismus, or vision therapy
- •History of neurolens or prism spectacle correction
- •History of significant vertical phoria or vertical phoria correction
- •Current ocular medication use
- •Significant signs of dry eye:
- •> Grad 1 ocular surface staining
- •Schirmer scores < 7 mm
- •Tear break up time < 7 seconds
- •Signs of inappropriate fit or surface of soft contact lenses
- •Insufficient movement centration, and/or coverage
- •Significant lens deposits
- •Signs of corneal or conjunctival contact-lens related complications
结局指标
主要结局
Change in Contact Lens Discomfort
时间窗: Baseline and 30-35 days
Change in contact lens discomfort measured by the Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8), Score range: 0 - 37 points, Higher scores indicate worse symptoms
次要结局
- Change in Convergence Insufficiency Symptoms(Baseline and 30-35 days)
- Change in Headache Symptoms(Baseline and 30-35 days)
- Change in Dry Eye Symptoms(Baseline and 30-35 days)
