In Vivo Molecular Imaging (MRI) of Atherothrombotic Lesions
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 886
- 试验地点
- 1
- 主要终点
- Correlation between imaging and biomarkers of atherosclerosis
研究概览
简要总结
The purpose of this study is to develop and validate novel magnetic resonance imaging (MRI), dynamic contrast enhanced (DCE)-MRI and positron emission tomography (PET)/MR techniques for the detection and risk stratification of patients with atherosclerosis.
详细描述
Atherosclerosis is responsible for the majority of disabilities and deaths in developed countries. Previous studies have shown that sudden clinical events correlate highly with plaque composition and the degree of plaque inflammation. These results stress the importance of developing non-invasive surrogate markers of plaque inflammation to detect asymptomatic high-risk plaques in clinical settings. Dynamic contrast enhanced (DCE) magnetic resonance imaging (MRI) and 18F fluorodeoxyglucose (FDG) positron emission tomography (PET) with combined computed tomography (CT) have shown promise in characterizing and quantifying metabolic activity (i.e., glycolysis/ inflammation) in atherosclerosis, by targeting the presence of neovessels (DCE-MRI) and inflammatory cells such as macrophages (18F-FDG PET) in plaques of both animal and human subjects. However, several challenges need to be overcome prior to translating these imaging approaches to clinical practice. A significant obstacle to adapting conventional DCE-MRI approaches to atherosclerosis includes the necessity to image with high spatial resolution to capture plaque heterogeneity. This can be achieved with longer scan times, but conflicts with need for high temporal resolution required for accurate arterial input function sampling and quantification of contrast agent uptake. In Aim 1, the investigators will develop and validate a novel dual-imaging sequence for DCE-MRI of atherosclerosis where the investigators acquire a high temporal resolution, but low spatial resolution, AIF image and a high spatial resolution/low temporal resolution vessel wall image to allow accurate quantification of contrast agent uptake within plaques. This approach will be compared to conventional approaches in both a rabbit model of atherosclerosis and in human subjects. The limited spatial resolution of conventional PET scanners has an impact on the accuracy of 18F-FDG PET quantification in atherosclerotic plaques because of the partial volume effect (PVE). A posteriori PVE correction methods using high-resolution anatomical images acquired with a different imaging modality can improve quantification, but are challenging since they require accurate co-registration between the another imaging modality and PET. MR is an ideal choice for this second imaging modality as it produces high-resolution anatomical images without the use of ionizing radiation. A combined MR/PET scanner may therefore be better suited for developing novel PVE correction methodologies. As part of Aim 2, the investigators will develop and validate the combined MR-PET(FDG) imaging approach to improve the quantification of atherosclerotic plaque metabolic activity. Attenuation correction based on MR will be compared with CT based attenuation correction. Approaches to improved PVE correction and optimal circulation time for plaque imaging will also be validated in both rabbits and humans. Finally, imaging parameters derived from the improved DCE-MRI and MR- PET(FDG) will be validated in patients undergoing carotid endarterectomy (CEA), with the primary endpoint of establishing the relationship between imaging and histological markers of plaque inflammation. Additionally, the investigators will assess the relationship (if any) with serum biomarkers and, as an exploratory endpoint, the investigators will study by real time PCR the relationship of imaging with the gene expression of markers of plaque vulnerability.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Cross Sectional
入排标准
- 年龄范围
- 20 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Volunteers with carotid artery disease who are MRI and CT compatible.
- •All subjects will have either a
- •clinical diagnosis of atherosclerosis,
- •and/or risk factors
- •and/or family history of disease
- •Exclusion criteria:
- •Glomerular filtration rate <30mg/ml (for MRI with contrast)
- •Subjects who have any ferromagnetic implants (e.g. aneurysm clip, ICD, pacemaker, etc.) or a condition that may be contraindicated for the MRI procedure (e.g. claustrophobia )
- •Pregnant patients will be excluded from the present study.
排除标准
- 未提供
结局指标
主要结局
Correlation between imaging and biomarkers of atherosclerosis
时间窗: 5 years
R correlation coefficient
次要结局
- DCE-MRI kinetic parameters(3 years)
- FDG uptake parameters(3 years)
研究者
Zahi Fayad
Professor
Icahn School of Medicine at Mount Sinai