Brief Summary

Prosthetic-driven immediate implant placement for optimal aesthetic restoration has been increasing in demand during the last decades but requires higher accuracy. Dynamic navigation has been a reported better implant positioning. There are two main choices of implant macrogeometry: straight and tapered implants. One feature of implant design that may influence implants' accuracy is the taper of the implant body. However, their exact role is still needed to be investigated further. Besides, implant macrogeometry may influence primary stability, which is a prerequisite in achieving osseointegration. Therefore, we designed a randomized controlled clinical trial study to verify the clinical efficacy of the implant macrogeometry by comparing straight implants with tapered implants in immediate implant placement using dynamic navigation.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
20
Inclusion Criteria
  1. ≥18 years old and in good health;
  2. The maxillary incisor that cannot be retained due to non-periodontitis;
  3. The buccal bone plate is complete;
  4. No acute infection;
  5. The extraction socket have at least 3-5 mm apical bone.
Exclusion Criteria
  1. General contraindications of oral implant surgery (such as immunodeficiency, long-term use of corticosteroids);
  2. Treatments or diseases that may affect bone tissue metabolism (for example, taking bisphosphonates or receiving local radiotherapy);
  3. Periodontitis history or uncontrolled periodontitis. Bleeding of probing (BOP) positive site ≥ 10%, or probing depth (PD) ≥ 4mm;
  4. Heavy smokers or previous heavy smoking history (quit smoking time <5 years or> 20 cigarettes per day);
  5. Refuse to participate in this trial.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
straight implantStraight Implants-
tapered implantTapered Implants-
Primary Outcome Measures
NameTimeMethod
Accuracyone week

mm

Secondary Outcome Measures
NameTimeMethod
Insetion torque value, ITVsurgery day

to detect primary stability

Implant Stability Quotient, ISQsurgery day

to detect primary stability

Trial Locations