Effect of Photobiomodulation by 808nm Diode Laser on the Stability of Orthodontic Mini-implants: A Randomized Clinical Split-Mouth Trial.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 22
- 试验地点
- 1
- 主要终点
- stability of orthodontic mini-implants
研究概览
简要总结
The study aimed to evaluate the influence of a 635nm diode laser on the stability of orthodontic mini-implants in vitro, as well as mini-implants failure rate (mini-implant loss) and patients pain level after the treatment. A randomized clinical split-mouth trial was concluded with 22 subjects (14 women, 8 men), 44 orthodontic mini-implants with a diameter 1.4mm and length of 10mm. Mini-implants were placed between teeth 3 and 4; and 13 and 14 (Universal Numbering System), in the area of the attached gingiva, 2 mm below mucogingival junction.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Single (Investigator)
入排标准
- 年龄范围
- 18 Years 至 60 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •patients with class II malocclusion defect requiring lateral maxillary teeth distillation based on the use of orthodontic mini-implant;
- •the patients were treated first time using fixed orthodontic appliance;
- •no systemic diseases;
- •were not using anti-inflammatory drugs;
排除标准
- •had used antibiotics in the previous 24 months;
- •had history of radiotherapy,
- •taking bisphosphonate medication
结局指标
主要结局
stability of orthodontic mini-implants
时间窗: 60 days
The mini-implants stability was estimated employing a Periotest device (Medzintechnik Gulden e K, Modautal, Germany). The Periotest measurement system includes the sound formed from contact between an object and a metallic tapping bar in a handpiece, which is electromagnetically driven and electronically verified. The Periotest response detection is analyzed through a fast Fourier transform (FFT) algorithm. Simply put, the Periotest answer to tapping is estimated by an accelerometer and then analyzed. The signal generated by tapping is then transformed to a value called the Periotest value (PTV), which depends on the damping characteristics of the peri-implant tissue. The Periotest Test values (PTVs) are based on a numerical scale ranging from -8 to +50, defined by mathematical computation. The lower Periotest values indicate higher implant stability and thereupon the higher absorption effect of the target objects.
次要结局
- mini-implants loss(60 days)
- Pain level (NRS scale)(24 hours)
研究者
Jacek Matys
Principal Investigator
Wroclaw Medical University