Photobiomodulation of Orthodontic Mini-implants by a 635nm Diode Laser: Primary and Secondary Stability. A Randomized Clinical Split-Mouth Trial.

Wroclaw Medical University1 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2019年2月2日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
15
试验地点
1
主要终点
stability of orthodontic mini-implants

研究概览

简要总结

The study aimed to estimate clinically an influence of 635nm diode laser on the primary and secondary stability of orthodontic mini-implants placed in a maxilla, to assess mini-implants failure rate (mini-implant loss) and to evaluate a pain level after the treatment. The randomized clinical split-mouth trial included 15 subjects, 30 implants (Dual Top Anchor System, Seoul, Korea) with a diameter 1.4mm and length of 10mm. Mini-implants were placed in the area of the attached gingiva between the second premolar and first molar teeth 2 mm below the mucogingival junction of both sides of the maxilla in 15 patients.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Investigator)

入排标准

性别
All
接受健康志愿者

入选标准

  • patients with class II malocclusion defect requiring lateral maxillary teeth distillation based on the use of orthodontic mini-implant;
  • the patients were treated first time using fixed orthodontic appliance;
  • no systemic diseases;
  • were not using anti-inflammatory drugs;

排除标准

  • had used antibiotics in the previous 24 months;
  • had history of radiotherapy,
  • taking bisphosphonate medication

结局指标

主要结局

stability of orthodontic mini-implants

时间窗: 60 days

The mini-implants stability was estimated employing a Periotest device (Medzintechnik Gulden e K, Modautal, Germany). The Periotest measurement system includes the sound formed from contact between an object and a metallic tapping bar in a handpiece, which is electromagnetically driven and electronically verified. The Periotest response detection is analyzed through a fast Fourier transform (FFT) algorithm. Simply put, the Periotest answer to tapping is estimated by an accelerometer and then analyzed. The signal generated by tapping is then transformed to a value called the Periotest value (PTV), which depends on the damping characteristics of the peri-implant tissue. \[27\] The Periotest Test values (PTVs) are based on a numerical scale ranging from -8 to +50, defined by mathematical computation. The lower Periotest values indicate higher implant stability and thereupon the higher absorption effect of the target objects.