The Effect of Extracorporeal Shock Wave Therapy After Botulinum Toxin Type A Injection for Post-stroke Spasticity
- Conditions
- Muscle SpasticityStrokeHemiplegia, Spastic
- Interventions
- Device: Extracorporeal shock wave therapyProcedure: Botulinum toxin treatment
- Registration Number
- NCT05889026
- Lead Sponsor
- Korea University Guro Hospital
- Brief Summary
There are few studies on whether botulinum toxin treatment and extracorporeal shock wave therapy are more effective than botulinum toxin alone treatment for post-stroke spasticity.
- Detailed Description
If the study results can be drawn that the group receiving extracorporeal shock wave therapy along with botulinum toxin treatment can increase the effect of botulinum toxin treatment and lengthen the treatment period compared to the group with botulinum toxin treatment only, it can be widely used as an auxiliary treatment for botulinum toxin treatment. This study was carried out with the expectation that it would be possible to provide a basis for this.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 16
- at least 6 weeks after stroke diagnosis
- upper-extremity (elbow, wrist and finger) spasticity Modified Ashworth Scale (MAS) score > 2
- ability to stand and walk safely without help or assistance
- improper indication for botulinum toxin A (BTxA) injection, for example, myasthenia gravis, Eaton-Lambert syndrome, amyotrophic lateral sclerosis, and motor neuropathy
- previous contracture and/or deformity of the upper extremities
- concurrent peripheral neuropathy and/or myopathy
- difficulty in participating in the study due to cognitive impairment.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Botulinum toxin treatment with extracorporeal shock wave therapy Extracorporeal shock wave therapy Nabota® (Daewoong Pharmaceutical Co. Ltd., Seoul, Korea) was used. It was diluted with 0.9% sodium chloride solution and injected into the bellies of the upper-extremity muscles. ESWT was performed immediately after botulinum toxin injection and was performed once a day for 5 days. Three weeks and 3 months after ESWT, spasticity was evaluated. Botulinum toxin treatment with extracorporeal shock wave therapy Botulinum toxin treatment Nabota® (Daewoong Pharmaceutical Co. Ltd., Seoul, Korea) was used. It was diluted with 0.9% sodium chloride solution and injected into the bellies of the upper-extremity muscles. ESWT was performed immediately after botulinum toxin injection and was performed once a day for 5 days. Three weeks and 3 months after ESWT, spasticity was evaluated. Botulinum toxin treatment only Botulinum toxin treatment Nabota® (Daewoong Pharmaceutical Co. Ltd., Seoul, Korea) was used. It was diluted with 0.9% sodium chloride solution and injected into the bellies of the upper-extremity muscles. Three weeks and 3 months after Botox treatment, spasticity was evaluated.
- Primary Outcome Measures
Name Time Method Modified ashworth scale of upper extremities spasticity Three months after treatment minimum grade 0, maximum grade 4 / higher grade means severe spasticity
- Secondary Outcome Measures
Name Time Method Fugl-Meyer assessment of upper extremity Fugl-Meyer assessment of upper extremity Fugl-Meyer assessment of upper extremity Fugl-Meyer assessment of upper extremity Pre-treatment (baseline) Minimum score 0, maximum score 66 / higher score means better function of upper extremity
Modified barthel index Three months after treatment Minimum score 0, maximum score 100 (if w/c ambulation, 90) / higher score means better capacity for activities of daily living
Modified tardieu scale of upper extremities spasticity Three months after treatment Unit : degree / higher degree means little limitation of range of motion
Fugl-Meyer assessment of upper extremity Three months after treatment Minimum score 0, maximum score 66 / higher score means better function of upper extremity
Action research arm test Three months after treatment Minimum score 0, maximum score 57 / higher score means better function of upper extremity
Trial Locations
- Locations (1)
Korea university guro hospital
🇰🇷Seoul, Korea, Republic of