Randomized Cross-over Comparison of Double Mini PET With Standard vs. Adapted Dwell Volume and Dwell Time - Proof of Concept of Adapted PD

Heidelberg University1 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2016年4月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
15
试验地点
1
主要终点
Dialytic sodium removal, i.e. the amount of sodium (mmol) per double mini PET (via ultrafiltration and diffusive sodium transport)

研究概览

简要总结

The purpose of this study is to validate the concept of adapted automated PD a modified Peritoneal Equilibration Test (PET), will be performed in children on chronic PD. Instead of a single 4 hour standard dwell, two double mini PET using the same type and total volume of dialysate and the same total dwell time (150min) will be performed in randomised sequence. An double mini test consists of two identical dwells, reflecting routine PD, the other one of a short small dwell followed by a long, large dwell as suggested from adapted PD regimes successfully applied in adult PD patients.

详细描述

Present peritoneal dialysis treatment is hampered by the limited efficacy of currently applied regimen, mainly consisting of a series of standard dwells with the same amount of dialysate and dwell time. New cycler machines available for routine therapy now allow modification of time and volume of each dwell and thus to individually adapt PD regime. In fact a recent multi-center trial in adult patients suggests that a PD regimen consisting of a sequence of short small dwells followed by large and long lasting dwells in total applying the same amount of dialysate during the same total treatment time substantially improves fluid and toxin removal. Underlying beneficial mechanisms are highly debated. Prior to adaptation of such PD treatment patterns to children on automated PD in the routine clinical setting, the tolerability and biochemical effects need to be demonstrated.

To this end, the Peritoneal Equilibration Test (PET), which is routinely performed in children during a day hospital treatment to analyse peritoneal transport function, will be modified. Instead of a single 4 hour standard dwell, two double mini PET using the same type and total volume of dialysate and the same total dwell time (150min) will be performed in randomised sequence in a total of 15 stable pediatric PD patients treated in four different European pediatric dialysis centres. The conventional double mini PET consists of two identical cycles (fill volume 1 L/m², 75 min), the adapted one of a short, small cycle (0.6 mL/m² BSA, 30 min) followed by a long, large cycle (1.4 mL/m², 120 min). A total of 22 ml of blood will be drawn via a peripheral i.v. line, intraperitoneal pressure, in clinical routine controlled once during a PET, will be measured with each dwell.

The study analyses the time and volume dependent PD transport mechanisms. Patients included may benefit from the detailed analysis of peritoneal membrane function, allowing for optimisation of the individual PD prescription.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
5 Years 至 21 Years(Child, Adult)
性别
All
接受健康志愿者
否

入选标准

  • •PD patients 5-21 years of age
  • •Stable PD
  • •Last peritonitis > 4 weeks ago

排除标准

  • •Polyuria and dehydrated patients (as to the clinical status RR, HR and BCM) not allowing for more than 1.5% glucose content of PD fluid
  • •Hypoalbuminemia (serum albumin < 25g/l)
  • •Relevant changes in dialysis regime and diet the three days preceding the study
  • •Hb < 9 mg/dl
  • •Pregnancy
  • •History of repeated hernia or PD fluid leakage
  • •Intolerability of intraperitoneal pressure of up to 18 cm H2O at 1400ml/m²
  • •BSA in supine position (e.g. due to organomegaly)
  • •Any underlying diseases affecting the peritoneal membrane transport function (such as previous surgery with subsequent adhesions and fluid trapping, chronic bowl disease)
  • •Heart insufficiency
  • •Patients with catheter dysfunction, i.e. outflow problems (assessed by cycler alarms during the last 2 weeks)

研究组 & 干预措施

Adapted double mini PET

Active Comparator

PET = Peritoneal Equilibration Test, a test routinely performed to measure peritoneal transport rates of solutes and water in peritoneal dialysis patients. To this end the routinely administered dialysis fluid is infused into the peritoneal cavity. The test will be modified (adapted):

A short, small cycle (0.6 mL/m² BSA, 30 min) followed by a long, large cycle (1.4 mL/m², 120 min) will be performed in each patient and compared to a standard double mini PET.

干预措施: Adapted double mini PET (Other)

Standard double mini PET

Placebo Comparator

The Standard double mini PET consists of two identical cycles (fill volume 1 L/m², 75 min of dwell time)

干预措施: Standard double mini PET (Other)

结局指标

主要结局

Dialytic sodium removal, i.e. the amount of sodium (mmol) per double mini PET (via ultrafiltration and diffusive sodium transport)

时间窗: 2 x 150 min with one 1 hour inbetween each PET

two double mini PET each comprising 150 min of dialysis

次要结局

  • dialytic water and solute removal, i.e. ultrafiltrate per double mini PET (ml/gram intraperitoneal glucose exposure), phosphate removal per dmPET (mmol); Kt/V, clearance of creatinine (ml/min*1.73m²), intraperitoneal pressure (cm water)(2 x 150 min with one 1 hour inbetween each PET)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Claus Peter Schmitt

Prof. Dr. med.

Heidelberg University

研究点 (1)

Loading locations...

相似试验

Proof of Concept of Adapted PD in Children (PC-AAPD) | 临床试验