Brief Summary

One method for treating intraoperative hypoxia during one-lung ventilation (OLV) is application of PEEP to the dependent lung. However, only a minority of patients benefit from this maneuver. The effect of applied PEEP on oxygenation depends on the relation between the total end-expiratory pressure and the lower inflexion point (LIP) of pressure-volume curve (1). LIP during OLV can be determined with super-syringe technique, but is too complicated for routine operating room use. An alternative is the constant-flow method which is easy and widely used in intensive care settings (2). The investigators goal was to confirm that the constant-flow method as applied by an intensive care ventilator works during OLV.

Methods: After IRB approval and written, informed consent, data were obtained from 20 patients during OLV for thoracic surgery who were ventilated with an AVEA (VIASYS Healthcare) critical-care ventilator. During two-lung ventilation (TLV) and OLV 8 ml•kg-1 tidal volume was used. During OLV, ventilation periods of ten minutes, with and without 5 cmH2O PEEP were alternated. During each period, the investigators recorded arterial blood partial pressures, respiratory and hemodynamic values, intrinsic PEEP (PEEPi), and LIP. PEEPi and LIP were determined using the automatic mode of the ventilator; specifically, LIP was determined with a continuous flow of 3L/minute.

Detailed Description

Not available

Recruitment & Eligibility

Status
WITHDRAWN
Sex
All
Target Recruitment
Not specified
Inclusion Criteria
  • thoracic surgery lung ventillation
Exclusion Criteria

Not provided

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
two-lung ventilation (TLV)two lung ventilation (TLV)During two-lung ventilation (TLV) and OLV 8 ml•kg-1 tidal volume was used.
one lung ventillation (OLV) without PEEPone lung ventilation (OLV) without PEEPDuring OLV, ventilation periods of ten minutes, with and without 5 cmH2O positive end-expiratory pressure (PEEP) were alternated.
one lung ventilation (OLV) with PEEPOne lung ventilation (OLV) with positive end-expiratory pressure (PEEP)During OLV, ventilation periods of ten minutes, with and without 5 cmH2Opositive end-expiratory pressure (PEEP) were alternated
Primary Outcome Measures
NameTimeMethod
intrinsic positive end-expiratory pressure (PEEP) during ventillation10 minutes

constant-flow method useful for determination of intrinsic positive end-expiratory pressure (PEEPi) during OLV

net change of Lower Inflexion Point (LIP)- intrinsic positive end-expiratory pressure (PEEPi) ditstance with PEEP10 minutes

Relationship between the net change of lower inflexion point (LIP)- positive end-expiratory pressure (PEEPi) ditstance with and without positive end-expiratory pressure (PEEP) and change of PaO2 is useful during OLV for determination of patients reaction for application extternal positive end-expiratory pressure (PEEP)

net change of lower inflexion point (LIP)-PEEPi ditstance without PEEP10 minutes

Relationship between the net change of lower inflexion point (LIP)-intrinsic positive end-expiratory pressure (PEEPi) ditstance with and without positive end-expiratory pressure (PEEP) and change of PaO2 is useful during one lung ventillation (OLV) for determination of patients reaction for application external positive end-expiratory pressure (PEEP).

lower inflexion point (LIP) of P-V curve during one lung ventillation (OLV)10 minutes