MedPath

Patient Self Measurement of Post-Void Residual Bladder Volume (PVR) Using Ultrasound

Not Applicable
Completed
Conditions
Voiding Dysfunction
Voiding Disorders
Interventions
Device: Butterfly portable ultrasound device with bladder ultrasound images
Device: Butterfly portable ultrasound device with abstract bladder images
Registration Number
NCT05295823
Lead Sponsor
Yale University
Brief Summary

This study would be the first to demonstrate feasibility, accuracy, reliability, clinical care impact, and patient satisfaction with remote monitoring of post-void residual bladder volume (PVR) using the Butterfly portable ultrasound device in patients with obstructive voiding dysfunction.

Detailed Description

This study would be the first to demonstrate feasibility, accuracy, reliability, and patient satisfaction with self measurement of PVR using the Butterfly portable ultrasound device.

In the current study protocol, participants will undergo routine clinical care with no additional clinical encounters for the purposes of this study. As part of routine clinical care, the patient will undergo 3 sequential measurements of patient PVR by the Urologic healthcare provider using the existing ultrasound technology, and a possible bladder catheterization for actual bladder volume measurement and to drain the bladder. Note that 3 sequential measurements are taken from which a mean and standard deviation are derived due to operator and technology-related variability in bladder volume measurement using ultrasound. Participants in the study will also undergo 3 sequential measurements of patient PVR by the Urologic healthcare provider using the Butterfly portable ultrasound device with ultrasound images of the bladder, and 3 sequential measurements of patient PVR by the Urologic healthcare provider using the Butterfly portable ultrasound device with abstract images of the bladder; and the participant will take 3 sequential self-measurements of PVR using the Butterfly portable ultrasound device with ultrasound images of the bladder and 3 sequential self-measurements of PVR using the Butterfly portable ultrasound device with abstract images of the bladder during the same clinic encounter. The Urologic healthcare provider might also perform a bladder catheterization of the patient to determine the actual PVR and to drain the bladder of the residual urine.

Ultimately, successful remote measurement of patient PVR may lead to a paradigm shift in how patients with voiding dysfunction are clinically monitored; and would be a critical tool in triaging patients with possible urinary retention at any time but most especially during a pandemic necessitating social distancing and judicious allocation of healthcare resources. Remote PVR measurement in patients with obstructive voiding dysfunction may lead to more accurate monitoring for urinary retention; early detection of and intervention for urinary retention and potential prevention of sequelae such as urinary tract infection/urosepsis, renal failure, and bladder failure; potential reduction in medical costs and travel burden by reducing unnecessary clinic and emergency room visits as well as the costs of treating potential sequelae of urinary retention; and better quality of life for patients with obstructive voiding dysfunction.

Ultrasound technology is non-invasive, uses sound waves (non-ionizing radiation) to produce a volume measurement, and is an exceptionally safe method of imaging with a very limited risk profile.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
50
Inclusion Criteria
  • Patient with capacity to consent to the study and completion of informed consent document
  • Ability to speak and read English
Read More
Exclusion Criteria
  • Patient without capacity to consent to the study or incompletion of informed consent document
  • Inability to speak and read English
Read More

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Self PVR measurement using Butterfly and bladder ultrasound imagesButterfly portable ultrasound device with bladder ultrasound imagesThe participant will perform self PVR measurement (3 consecutive measurements during the same encounter) using the Butterfly and bladder ultrasound images (prior to catheterization, if needed)
Healthcare provider performed PVR measurement using Butterfly and abstract bladder imagesButterfly portable ultrasound device with abstract bladder imagesThe Urologic healthcare provider will perform PVR measurement on the participant (3 consecutive measurements during the same encounter) using the Butterfly and abstract bladder images
Healthcare provider performed PVR measurement using Butterfly and bladder ultrasound imagesButterfly portable ultrasound device with bladder ultrasound imagesThe Urologic healthcare provider will perform PVR measurement on the participant (3 consecutive measurements during the same encounter) using the Butterfly and bladder ultrasound images
Self PVR measurement using Butterfly and abstract bladder imagesButterfly portable ultrasound device with abstract bladder imagesThe participant will perform self PVR measurement (3 consecutive measurements during the same encounter) using the Butterfly and abstract bladder images (prior to catheterization, if needed)
Primary Outcome Measures
NameTimeMethod
Accuracy of self-measurement of PVR using the Butterfly with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the Butterfly with abstract bladder images measured by Bland-Altman analysis.up to 6 months

Accuracy of the patient self-measurement of PVR using the Butterfly portable ultrasound device with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the Butterfly portable ultrasound device with abstract bladder images during the same encounter. It is measured by Bland-Altman analysis which describes agreement between two quantitative measurements. More agreement means less difference between measurements.

Accuracy of self-measurement of PVR using the Butterfly with bladder ultrasound images compared to the Butterfly with abstract bladder images measured by Bland-Altman analysis.up to 6 months

Accuracy of the patient self-measurement of PVR using the Butterfly portable ultrasound device with bladder ultrasound images compared to the Butterfly portable ultrasound device with abstract bladder images during the same encounter. It is measured by Bland-Altman analysis which describes agreement between two quantitative measurements. More agreement means less difference between measurements.

Accuracy of self-measurement of PVR using the Butterfly with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the Butterfly with bladder ultrasound images measured by Bland-Altman analysis.up to 6 months

Accuracy of the patient self-measurement of PVR using the Butterfly portable ultrasound device with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the Butterfly portable ultrasound device with bladder ultrasound images during the same encounter. It is measured by Bland-Altman analysis which describes agreement between two quantitative measurements. More agreement means less difference between measurements.

Accuracy of patient self-measurement of PVR using the Butterfly with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the existing ultrasound technology measured by Bland-Altman analysis.up to 6 months

Accuracy of the patient self-measurement of PVR using the Butterfly portable ultrasound device with bladder ultrasound images compared to the healthcare provider's measurements of patient PVR using the existing ultrasound technology during the same encounter. It is measured by Bland-Altman analysis which describes agreement between two quantitative measurements. More agreement means less difference between measurements.

Accuracy of patient self-measurement of PVR using the Butterfly with bladder ultrasound images compared to the healthcare provider's bladder catheterization of the patient measured by Bland-Altman analysis.up to 6 months

Accuracy of the patient self-measurement of PVR using the Butterfly portable ultrasound device with bladder ultrasound images compared to the healthcare provider's measurements from bladder catheterization of the patient during the same encounter. It is measured by Bland-Altman analysis which describes agreement between two quantitative measurements. More agreement means less difference between measurements.

Secondary Outcome Measures
NameTimeMethod
Patient Reported Outcomes Questionnaire to asses ease of use, satisfaction, and preference of Butterfly Deviceup to 6 months

Patient Reported Outcomes Questionnaire to assess patient-reported ease of use, satisfaction, and preference between using bladder ultrasound images or abstract bladder images for self measurement of PVR with the Butterfly device using a patient questionnaire at the conclusion of patient self measurements. A mix of open-ended and multiple-choice questions using a 5-point Likert scale of responses.

Trial Locations

Locations (1)

Yale New Haven Hospital

🇺🇸

New Haven, Connecticut, United States