Oran Park Mask External Clinical Study (3) Marketing Claims Study
- Conditions
- Obstructive Sleep Apnea
- Interventions
- Device: Mask A (Oran Park Mask) then Mask B (Evora Mask)Device: Mask B (Evora Mask) then Mask A (Oran Park Mask)
- Registration Number
- NCT06079866
- Lead Sponsor
- ResMed
- Brief Summary
The goal of this prospective, randomized, open label, cross over study to assess the seal, comfort, usability, and performance of the prototype Oran Park mask system (referred to as Mask A in this study protocol) in the home environment. Comparisons will be made against Fisher \& Paykel's Evora Full mask system (referred to as Mask B in this study protocol, an FDA cleared benchmark mask) and the participant's own mask.
Patients diagnosed with Obstructive Sleep Apnea and are current CPAP users on a tube down full-face mask system will be recruited to the study to evaluate the Oran Park mask system and the Evora Full mask system for up to 7 nights each, in the home environment, whilst using their own CPAP device.
The overall purpose is to evaluate the performance of the prototype Oran Park mask system compared to an FDA cleared benchmark mask (Evora Full) in relation to seal, comfort, usability, ease of use, preference, AHI, and objective therapy data.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 58
-
Participants willing to give written informed consent
-
Participants who can read and comprehend English
-
Participants who ≥ 18 years of age
-
Participants being treated for OSA for ≥ 12 months
-
Participants who have met CMS compliance for CPAP therapy over the last 3 months
-
Participants who have been using a ResMed cloud connected AirSense10 or AirSense 11 device compatible with AirView, for more than 12 months
-
Participants currently using a suitable mask system*
-
Participants who can trial the masks for up to 7 nights each
- Note*: Suitable mask system includes any tube down full face mask (e.g. AirFit F30, AirFit F20, AirTouch F20, AirFit F10, Quattro Air, Quattro Fx, Mirage Quattro, Simplus, Amara, Amara Gel, Comfort gel Full Face Mask, Evora Full)
- Participants using Bi-level flow generators
- Participants who are or may be pregnant
- Participants with a pre-existing lung disease/ condition that would predispose them to pneumothorax (for example: COPD, lung cancer; fibrosis of the lungs; recent (< 2years) case of pneumonia or lung infection; lung injury.
- Participants who or whose bed partner has implantable metallic implants in the head, neck and chest region affected by magnetic fields (Non-ferrous implants may be acceptable)
- Participants who use a rental unit for AirSense 10 or AirSense 11 device
- Participants believed to be unsuitable for inclusion by the researcher
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Arm && Interventions
Group Intervention Description Mask A (Oran Park Mask) then Mask B (Evora Mask) Mask A (Oran Park Mask) then Mask B (Evora Mask) Participants will be randomized as to the order they will trial Mask A and Mask B. This arm will first use the Oran Park mask for 7 days and then use the Evora Mask for 7 days. Mask B (Evora Mask) then Mask A (Oran Park Mask) Mask B (Evora Mask) then Mask A (Oran Park Mask) Participants will be randomized as to the order they will trial Mask A and Mask B. This arm will first use the Evora mask for 7 days and then use the Oran Park mask for 7 days.
- Primary Outcome Measures
Name Time Method 11 point Likert Scale Questionnaire 7 days • Subjective scores will be collected from subjects on each attribute being assessed (e.g. seal, comfort, ease of use etc.). Scores will be collected using an 11-point Likert Scale Questionnaire. Minimum value will be zero. Maximum value will be 10. A higher score indicates better outcomes. A score of 10 is considered very favorable, and a score of 0 is very unfavorable.
- Secondary Outcome Measures
Name Time Method Pressure Differences 7 days The median air pressure (cmH2O) used during PAP therapy recorded by the subject's PAP device while using their own mask will be compared to the median air pressure (cmH2O) recorded by the subject's PAP device while using the Oran Park mask and the Evora mask. The median air pressure levels will be obtained from the ResMed AirView Compliance Reports downloaded from the subject's PAP device during the study visits.
Leak 7 days The median air leak (L/minute) recorded by the subject's PAP device while using their own mask will be compared to the median air leak (L/minute) recorded by the subject's PAP device while using the Oran Park mask and the Evora mask. The median air leak will be obtained from the ResMed AirView Compliance Reports downloaded during the study visits.
Apnea Hypopnea Index (AHI) 7 days • The AHI recorded by the subject's PAP device while using their own mask will be compared to the AHI recorded by the subject's PAP device while using the Oran Park mask and the Evora Mask. The AHI will be obtained from the ResMed AirView Compliance Reports downloaded from the subject's PAP device during the study visits.
Compliance 7 days The subject's average daily hours of use of PAP therapy recorded by the subject's PAP device while using their own mask will be compared to the average daily hours of use recorded by the subject's PAP device while using the Oran Park mask and the Evora mask. The average daily hours of use will be obtained from the ResMed AirView Compliance Reports downloaded from the subject's PAP device during the study visits.
Trial Locations
- Locations (2)
Clayton Sleep Institute
🇺🇸Saint Louis, Missouri, United States
Sleep Data
🇺🇸San Diego, California, United States