Determine Functions of Pinhole Glasses on the Eyes
- Conditions
- Vision, Ocular
- Registration Number
- NCT02111356
- Lead Sponsor
- Chung-Ang University Hosptial, Chung-Ang University College of Medicine
- Brief Summary
Pinhole glasses which is using pinhole effect may induce a functional change on the eyes, including Distance and near visual acuity(DVA, NVA), Pupil size, DOF, Accomodative amplitude, CS, Visual field(VF), Stereopsis.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 30
- Age : between 20 and 50 years old
- Visual acuity : correctable distant and near visual acuity by glasses up to 20/20
- Others : Normal intraocular pressure, optic discs with a healthy appearance, and normal ocular alignment.
- History of systemic or topical medication that might affect accommodation
- Others : Corneal pathologic features, previous ocular surgery, glaucomatous optic discs, glaucoma, cataracts of grade II or greater, vitreous opacity, or retinal abnormalities that might limit the accuracy of test.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Primary Outcome Measures
Name Time Method Distance and near visual acuity(DVA, NVA) Change from baseline at 1 week Check distance(4m) and near(40cm) visual acuity using Snellen chart, Visual Acuity chart 2000, respectively.
At 1 week, cheked with wearing the pinhole glasses (Trayner Pinhole Glasses, Trayner Glasses, U.K.)
- Secondary Outcome Measures
Name Time Method Depth of focus Change from baseline at 1 week Check with 4m Snellen chart.
At 1 week, cheked with wearing the pinhole glasses (Trayner Pinhole Glasses, Trayner Glasses, U.K.)Accomodation Change from baseline at 1 week check by Donder's push-up method. The subject was instructed to view the target letter (20/20 reduced Snellen number), which initially was positioned at approximately 40 cm. The target then was moved progressively closer to the patient's eye at approximately 5 cm per second until the subject noticed the target starting to blur.
At 1 week, cheked with wearing the pinhole glasses (Trayner Pinhole Glasses, Trayner Glasses, U.K.)Visual field Change from baseline at 1 week Humphrey Visual Field Analyzer (Carl Zeiss Meditec, Inc., Dublin, CA, USA) using a 30-2 Swedish Interactive Threshold Algorithm
At 1 week, cheked with wearing the pinhole glasses (Trayner Pinhole Glasses, Trayner Glasses, U.K.)Contrast sensitivity Change from baseline at 1 week CSV-1000E Contrast Testing Instrument (VectorVision, Dayton, OH, USA) at 2.5m distance under the standard brightness (85 cd/m2)
At 1 week, cheked with wearing the pinhole glasses (Trayner Pinhole Glasses, Trayner Glasses, U.K.)Stereopsis Change from baseline at 1 week Randot Stereotest (Stereo Optical Co, Chicago, Illinois, USA)
At 1 week, cheked with wearing the pinhole glasses (Trayner Pinhole Glasses, Trayner Glasses, U.K.)Pupil size Change from baseline at 1 week Check the pupil size using WASCA Analyzer(Carl Zeiss Meditec, Germany)
Trial Locations
- Locations (1)
Department of Ophthalmology, Chung-Ang University School of Medicine, Chung-Ang University Hospital
🇰🇷Seoul, Korea, Republic of
Department of Ophthalmology, Chung-Ang University School of Medicine, Chung-Ang University Hospital🇰🇷Seoul, Korea, Republic of