MedPath

Evaluating the Role of the Guidewire in Peripheral Intravenous Access

Not Applicable
Withdrawn
Conditions
Peripheral Intravenous Vein Catheter Phlebitis
Intravenous Infection
Registration Number
NCT04949854
Lead Sponsor
William Beaumont Hospitals
Brief Summary

This study is to demonstrate that the control ultralong intravenous catheter without the guide wire is equivalent to the experimental catheter with the guide wire. The hypothesis of this study is that the 6.35 cm 20G ultralong Ultrasound Guided Peripheral Intravenous (USPIV) will have no difference in survival compared to the 5.71 cm ultralong with wire USPIV.

Detailed Description

Peripheral intravenous catheter (PIVC) insertion is a standard hospital procedure that enables providers to rapidly administer fluids, medications, or blood products directly into a patients vein. This allows patients who have difficulty with tolerating oral intake or patients who are being prepared for surgery to still receive the proper treatments. Furthermore, because many medications are not designed to be administered orally, a PIVC is often used.

Despite being a common procedure, PIVC insertion routinely fails with failure rates of traditional blind intravenous (IV) catheter placement ranging from 19%-29.9%. Common causes of failure include infiltration, occlusion, dislodgement, phlebitis, and infection. In addition to increasing costs, multiple placements of an IV catheter during a hospital stay places a considerable time burden on hospital staff. One effort to alleviate this burden has been the introduction of ultrasound, which is shown to help mitigate failure rates of PIVC placement in patients with difficult vascular access. .

The catheter length in vein is the single most relevant variable in determining catheter survival in USPIV insertions. IV Catheter survival depends on the length of the catheter inside the veins. Vein depth and angle of insertion play a significant role in choosing the right catheter length to achieve the ideal quantity of catheter in vein. When a shallow angle is used, the catheter distance to the vein also increases and longer catheters are needed to achieve the optimal 2.75 cm in vein. Unfortunately, the longest most commonly stocked peripheral IV catheter at most institutions is 4.78 cm. This length is inadequate for insertions with a vein depth of greater than approximately 0.75 cm. As this is a commonly encountered vein depth, longer peripheral IV catheters are needed to ensure improved catheter survival.Few peripheral intravenous catheter options exist with the Ultra Long profile. The 6.35 cm B. Braun deep access device and the BD 5.71 cm Accucath device are two commercially available options for this category of ultra long peripheral IVs. Both catheters are available and being used in Beaumont Hospital.The 6.35 cm option is similar to other peripheral IV catheters and is inserted using the same technique applied for all ultrasound guided IV insertions. The 5.71 cm option is similar to other peripheral IVs with the additional feature of a built-in wire within the device to help guide the catheter in the vein once the needle has penetrated the vein. The cost of the 5.71 cm option is approximately ten times the cost of the 6.35 cm device.

Adult patients with a Vascular Access Score of 4 or 5 (where Score 1= Visible with distention and easily palpable; Score 2=Visible and easily palpable; Score 3= Not visible and easily palpable; Score 4=Visible and poorly palpable and Score 5=Not visible and poorly or non-palpable) will be approached for inclusion in the study.

Recruitment & Eligibility

Status
WITHDRAWN
Sex
All
Target Recruitment
Not specified
Inclusion Criteria

Not provided

Exclusion Criteria

Not provided

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Primary Outcome Measures
NameTimeMethod
Catheter survivalDuring hospitalization, up to 60 days

Survival in hours or days of the catheter will be evaluated by functionality of catheter for intravenous therapy prior to patient discharge. The event of interest is failure of functionality identified during follow-up assessment during hospitalization.

Secondary Outcome Measures
NameTimeMethod
Time to insertionFirst day of hospitalization

Time to insertion (measured in minutes) is defined as needlestick to dressing application.

Provider proficiencyStudy period, a maximum of 1 year

Change in mean number of attempts per patient for successful insertion, from baseline mean for first three patients attempted to last three patients attempted.

Total cost for all vascular access needs during hospitalization.During hospitalization, up to 60 days

Cost per patient for vascular access during hospitalization, comprising (i) direct costs of IV insertion based on estimated labor and material cost per insertion attempt and estimated similar costs for rescue devices if needed and (ii) cost of treatment based on estimated cost per hour.

First-stick success.First day of hospitalization

Number of patients with only one puncture of skin to achieve venous access

Catheter-associated bloodstream infectionDuring hospitalization, up to 60 days

The number of patients with catheter-associated bloodstream infection. Cases of infection will be diagnosed per laboratory confirmed bloodstream infection criteria published by the National Healthcare Safety Network (NHSN) and identified by the Department of Epidemiology at Beaumont Hospital.

Catheter-associated thrombosisDuring hospitalization, up to 60 days

The number of patients with all symptomatic catheter related upper extremity venous thrombosis inclusive of superficial thrombophlebitis (SVT), deep venous thrombosis(DVT), and pulmonary embolism will be confirmed by upper extremity doppler evaluation, computed tomography, and/or ventilation perfusion testing.

Trial Locations

Locations (1)

Beaumont Hospitals

🇺🇸

Royal Oak, Michigan, United States

Beaumont Hospitals
🇺🇸Royal Oak, Michigan, United States