跳至主要内容
临床试验/NCT04008940
NCT04008940已完成不适用

A Retrospective Radiological Analysis of the Mechanical Performance of Different Locking Plates in Distal Femoral Fractures

AO Innovation Translation Center4 个研究点 分布在 2 个国家目标入组 100 人开始时间: 2012年1月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
100
试验地点
4
主要终点
Fracture

研究概览

简要总结

In order to assess the rate and mode of failure cases observed in patients with distal femur fractures treated with a distal femur plates, anonymized radiographs from those patients will be collected retrospectively.

All available images will reviewed by an expert review board in regards to fracture classification, implant and surgery details, quality of initial reduction and plate positioning as well as the occurrence of mechanical complications and the outcome in terms of fracture healing (if available). Additionally, age and gender as basic demographical data will be collected in a de-identified way..

详细描述

Severely comminuted distal femur fractures can be challenging injuries and usually require surgical treatment with lateral distal plate osteosynthesis.

Anatomically pre-contoured locking plates are commonly used. In 2012, the 4.5mm VA-LCP Curved Condylar Plate for distal femur fractures (VA-LCP DF, Synthes) was introduced offering the option of axis variation of the locking screws.

Recently, a report highlighted cases of implant failure with this implant, cautioning practicing surgeons against the use of this implant in certain type of AO/OTA fracture and dislocation classification 33 fractures (AO/OTA classification).

Based on this report, the current study was designed to perform a retrospective in-depth radiological analysis of all cases distal femur fractures of 4 participating sites in which the VA-LCP DF, the LCP Distal Femur Plate (LCP DF, Synthes) or the 'less invasive stabilization system' for distal femur fractures (LISS DF, Synthes) were used for fracture stabilization. The radiological in-depth analysis will be done by an expert review board with the aim to identify potential causes and risk factors for the failure cases among all cases collected.

This evaluation will contribute to a better understanding of the mechanical performance of distal femur fracture plates and the causes and risk factors for failures.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age 18 years and older
  • Diagnosis of a distal femur fracture type OTA/AO classification 33-A, -B, -C
  • uni- or bilateral
  • low or high energy trauma
  • Open or closed fractures
  • Surgical treatment with the VA-LCP DF, LISS DF, LCP DF
  • Available radiographical documentation, beginning with the injury radiographs, ending with the documented healing or any documented failure with or without revision surgery (up to a maximum follow-up of 1 year

排除标准

  • 未提供

结局指标

主要结局

Fracture

时间窗: baseline

type of fracture

Bone union in time

时间窗: baseline until 1 year

weeks to bone union

Mechanism of injury

时间窗: baseline

High energy trauma (H) or low energy trauma assessed as H for high and L for low energy trauma

Fracture classification

时间窗: baseline

AO/OTA classification 33A, -B or C

Implant used

时间窗: baseline

Implant manufacturer name (VA-LCP DF, LISS DF, LCP DF)

Open or closed fracture

时间窗: 1 year

G-A class: Y=open, N=closed

次要结局

未报告次要终点

研究者

发起方
AO Innovation Translation Center
申办方类型
Other
责任方
Sponsor

研究点 (4)

Loading locations...

相似试验