Dimensional Changes of Alveolar Ridge After Tooth Extraction Using the Socket Shield Technique Without Immediate Implant Placement.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 80
- 试验地点
- 2
- 主要终点
- Alveolar Ridge Width Changes
研究概览
简要总结
This study aimed to evaluate the dimensional changes in the alveolar ridge after tooth extraction using the socket shield technique without immediate implant placement. The changes using CBCT were assessed, focusing on the preservation of the ridge for delayed implant placement. This research could help improve dental implant outcomes by preserving bone and soft tissue structures."
详细描述
"In this clinical trial, the dimensional changes in the alveolar ridge following tooth extraction were investigated using the socket shield technique. The socket shield technique involved partial retention of the root structure to preserve the surrounding bone and soft tissues. No immediate implant placement was performed, and the ridge changes were assessed at multiple time points through CBCT scans. The study included a specified sample size, and participants underwent a follow-up of 6 months after socket shield preparation. This research aimed to provide insights into how well the socket shield technique preserves ridge dimensions over time, potentially optimizing future implant stability."
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 18 Years 至 70 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Non-restorable teeth in the esthetic region.
- •The buccal periodontal tissues were intact.
- •Maintaining oral hygiene.
排除标准
- •The usual limitations for oral surgery.
- •Tooth having a vertical fracture of the root on the facial aspect.
- •Tooth having horizontal fracture of the root extending below the level of the bone.
- •Caries on the root segment to be maintained.
- •Mobility of the tooth.
结局指标
主要结局
Alveolar Ridge Width Changes
时间窗: 6 months post-extraction
This outcome measure assesses changes in the alveolar ridge width following tooth extraction using either the modified socket shield technique or conventional extraction. Measurements were obtained through CBCT imaging at baseline and 6 months post-extraction. Unit of Measure: Millimeters (mm)
Bone Plate Height Changes
时间窗: 6 months post-extraction
This outcome measure assesses changes in the bone plate height following tooth extraction using either the modified socket shield technique or conventional extraction. Measurements were obtained through CBCT imaging at baseline and 6 months post-extraction. Unit of Measure: Millimeters (mm)
次要结局
- Primary Implant Stability(At the time of implant placement, typically 6 months post-extraction.)
研究者
Soaad Tolba Mohammed Tolba Badawi
Lecturer of Oral and maxillofacial Surgery, Faculty of dentistry, Mansoura university.
Mansoura University
