MedPath

Washing Pipe with a Spray Nozzle for Topical Anesthesia During Bronchoscopy

Not Applicable
Completed
Conditions
Pulmonary Disease
Interventions
Device: Washing Pipe With a Spray Nozzle
Registration Number
NCT05970848
Lead Sponsor
National Taiwan University Hospital
Brief Summary

The goal of this randomized control trial is to evaluate the effectiveness and safety of using a spray nozzle, compared to the conventional method, for topical anesthesia by the spray-as-you-go technique in reducing cough frequency, improving cough, discomfort, tolerance, satisfaction, reducing the dosage of lidocaine consumption of patients during flexible bronchoscopy.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
126
Inclusion Criteria
  1. Age 18 years or older
  2. A planned flexible bronchoscopy
  3. Being able to communicate with Mandarin Chinese or Taiwanese Hokkien
Exclusion Criteria
  1. are unwilling to join the study
  2. have tracheostomy or are intubated
  3. will receive intravenous anesthesia during flexible bronchoscopy
  4. known to be pregnant

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Group SWashing Pipe With a Spray NozzleGroup S patients will receive topical lidocaine anesthesia via the spray nozzle by the spray as-you-go technique during flexible bronchoscopy.
Primary Outcome Measures
NameTimeMethod
Cough rateThrough the duration of the bronchoscopy exam, an average of 30 min

The bronchoscopy procedure will be audio-taped throughout and cough counting will be recorded by an investigator blinded to the patient information and grouping. The cough rate will be calculated as total cough counts divided by procedure time in minute.

Secondary Outcome Measures
NameTimeMethod
Adverse eventsThrough the duration of the bronchoscopy exam, an average of 30 min

Development of adverse events during the bronchoscopic procedure, such as bleeding and oxygen desaturation

Procedure timeThrough the duration of the bronchoscopy exam, an average of 30 min

The duration (minute) of the bronchoscopic procedure

Lidocaine dosageThrough the duration of the bronchoscopy exam, an average of 30 min

Total lidocaine doses dispensed during the bronchoscopic procedure

Patient satisfactionThrough the duration of the bronchoscopy exam, an average of 30 min

Using a visual analogue scale from 0 to 10 to indicate patient satisfaction of the bronchoscopy

Patient toleranceThrough the duration of the bronchoscopy exam, an average of 30 min

Using a visual analogue scale from 0 to 10 to indicate patient tolerance of the bronchoscopy