Washing Pipe with a Spray Nozzle for Topical Anesthesia During Bronchoscopy
- Conditions
- Pulmonary Disease
- Interventions
- Device: Washing Pipe With a Spray Nozzle
- Registration Number
- NCT05970848
- Lead Sponsor
- National Taiwan University Hospital
- Brief Summary
The goal of this randomized control trial is to evaluate the effectiveness and safety of using a spray nozzle, compared to the conventional method, for topical anesthesia by the spray-as-you-go technique in reducing cough frequency, improving cough, discomfort, tolerance, satisfaction, reducing the dosage of lidocaine consumption of patients during flexible bronchoscopy.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 126
- Age 18 years or older
- A planned flexible bronchoscopy
- Being able to communicate with Mandarin Chinese or Taiwanese Hokkien
- are unwilling to join the study
- have tracheostomy or are intubated
- will receive intravenous anesthesia during flexible bronchoscopy
- known to be pregnant
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Group S Washing Pipe With a Spray Nozzle Group S patients will receive topical lidocaine anesthesia via the spray nozzle by the spray as-you-go technique during flexible bronchoscopy.
- Primary Outcome Measures
Name Time Method Cough rate Through the duration of the bronchoscopy exam, an average of 30 min The bronchoscopy procedure will be audio-taped throughout and cough counting will be recorded by an investigator blinded to the patient information and grouping. The cough rate will be calculated as total cough counts divided by procedure time in minute.
- Secondary Outcome Measures
Name Time Method Adverse events Through the duration of the bronchoscopy exam, an average of 30 min Development of adverse events during the bronchoscopic procedure, such as bleeding and oxygen desaturation
Procedure time Through the duration of the bronchoscopy exam, an average of 30 min The duration (minute) of the bronchoscopic procedure
Lidocaine dosage Through the duration of the bronchoscopy exam, an average of 30 min Total lidocaine doses dispensed during the bronchoscopic procedure
Patient satisfaction Through the duration of the bronchoscopy exam, an average of 30 min Using a visual analogue scale from 0 to 10 to indicate patient satisfaction of the bronchoscopy
Patient tolerance Through the duration of the bronchoscopy exam, an average of 30 min Using a visual analogue scale from 0 to 10 to indicate patient tolerance of the bronchoscopy
Trial Locations
- Locations (1)
National Taiwan University Hospital
🇨🇳Taipei, Taiwan