Skip to main content
Clinical Trials/NCT01268982
NCT01268982
Completed
Phase 2

Dimensional Changes of the Alveolar Ridge Contour After Socket Preservation, Stability of Implants Placed, and Histological Evaluation of Newly Formed Bone at These Sites.

Mashhad University of Medical Sciences1 site in 1 country32 target enrollmentJanuary 2010

Overview

Phase
Phase 2
Intervention
Not specified
Conditions
Alveolar Bone Atrophy
Sponsor
Mashhad University of Medical Sciences
Enrollment
32
Locations
1
Primary Endpoint
soft and hard tissue vertical and horizontal changes
Status
Completed
Last Updated
15 years ago

Overview

Brief Summary

In this study, the investigators will evaluate the dimensional changes of alveolar bone in the preserved sites in comparison with extraction only conventional healed sockets, as well.

  1. Dimensional changes of the alveolar ridge contour after socket preservation in comparison to conventional tooth extraction.
  2. Evaluation the stability of implants placed at the preserved sockets.
  3. Histological evaluation of newly formed bone at the socket preserved sites in comparison with extracted only healed sites.

Detailed Description

Nineteen systematically healthy patients (10 female and 9 male; mean age 38 years old; range 19-57) providing 32 hopeless non-molar teeth were selected and divided into 2 treatment groups: In the test group, following tooth extraction, for 16 sockets (9sockets from 5 female and 7 sockets from 5 male patients) soft and hard tissue measurements include horizontal (Bucco-Lingual dimensions at 1mm,3mm and 7mm at the mid portion from the line connecting two adjacent CEJs) and vertical ridge dimensions (vertical distance from the line connecting two adjacent CEJs at 8 points: Mid-Buccal, Mid-Lingual, Mesial, Distal, Disto-Buccal, Disto-Lingual, Mesio-Buccal, Mesio-Lingual around the socket) will be determined using a caliper and a template. All sockets will be filled with DFDBA and covered with absorbable membrane. Primary coverage will be achieved by full thickness mucosal flap advancement over each socket. Then an acid-etch bridge will be applied for the sites, both to avoid the movement of adjacent teeth to the empty space \& also for patients esthetics. 6 months following the procedure, the soft and hard tissue in all the sites will be measured again as it was mentioned previously, plus the measurements gained from CBCT radiographs. Besides, biopsy will be harvested from some of the preserved sites that has enough width with the use of trephine bur no.3 and it was sent for histological evaluation. Subsequently, Implants will be installed in the preserved sites and the implant stability will be measured with the help of Ostell device. The stability will be measured after 4 month following implant insertion with the same device while the implant undergoes the implant exposure procedure. In control group, 16 sockets (9 sockets from 5 female, and 7 sockets from 4 male patients) served as unfilled extraction only group. Following extraction, soft and hard tissue measurements (horizontal and vertical ridge dimensions) will be determined with the use of caliper and template. 6month after extraction, CBCT will be taken from the site and at the time of implant installation, the soft and hard tissue in all sites will be measured in vertical and horizontal dimensions. Furthermore, biopsy from some of the healed sockets with enough width will be taken with the use of trephine bur no.3 and it will be sent for histological examination.

Registry
clinicaltrials.gov
Start Date
January 2010
End Date
December 2010
Last Updated
15 years ago
Study Type
Interventional
Study Design
Parallel
Sex
All

Investigators

Eligibility Criteria

Inclusion Criteria

  • Non-molar hopeless teeth
  • lack of bone volume for ideal implant placement

Exclusion Criteria

  • Patient's un-wiliness for involvement in the project
  • contraindication of surgery due to medically-related problems

Outcomes

Primary Outcomes

soft and hard tissue vertical and horizontal changes

Time Frame: 6 months

soft and hard tissue measurements include horizontal (Bucco-Lingual dimensions at 1mm,3mm and 7mm at the mid portion from the line connecting two adjacent CEJs) and vertical ridge dimensions (vertical distance from the line connecting two adjacent CEJs at 8 points: Mid-Buccal, Mid-Lingual, Mesial, Distal, Disto-Buccal, Disto-Lingual, Mesio-Buccal, Mesio-Lingual around the socket)

Secondary Outcomes

  • histologic evaluation and implant stability measurement(10 months)

Study Sites (1)

Loading locations...

Similar Trials