跳至主要内容
临床试验/NCT05182294
NCT05182294已完成不适用

Tolerance and Acute Effects of a New HFNT Nasal Cannula on Comfort, Vital Signs, Breathing Pattern and Gas Exchange in Patients Hospitalized With an Acute Exacerbation of COPD

Temple University1 个研究点 分布在 1 个国家目标入组 14 人开始时间: 2022年5月25日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
14
试验地点
1
主要终点
Determining the level of comfort experienced by the patient of using high-flow nasal oxygen administered by two different nasal cannulas.

研究概览

简要总结

In the care of patients experiencing an acute exacerbation of COPD, supplemental oxygen therapy is often required. Oxygen is typically administered at flow rates between 1 and 4 liters per minute. High-flow nasal therapy (HFNT) has been reported to have beneficial effects in patients with hypoxemic respiratory failure and in hospitalized and non-hospitalized patients with severe COPD. Clinical efficacy in improving gas exchange depends upon patient tolerance and device-related properties such as flow rate and creation of turbulent flow in the conducting airways to improve oxygenation and carbon dioxide elimination. Alterations of nasal prong structure, such as nasal prong dimensions, may produce more robust turbulent flow at lower flow rates thereby improving gas exchange as well as patient tolerance. In this pilot study we will assess the impact of a new nasal cannula with asymmetric cannula dimensions that may create more turbulent flow at lower flow rates compared to the current symmetric nasal cannula on patient comfort as well as vital signs, pulse oximetry, breathing pattern and parameters of gas exchange in hospitalized patients with a COPD exacerbation.

详细描述

AIRVO 2: The AIRVO 2 is a humidifier with integrated flow generator that delivers warmed and humidified respiratory gases to spontaneously breathing patient through a variety of patient interfaces. This is an FDA-approved 510k device for use in hospitals and nursing homes. During HFNT, oxygen will be passed through a heated humidifier (AIRVO 2, Fisher and Paykel Healthcare) and applied continuously through conventional large-bore binasal symmetric prongs or the new asymmetric prongs cannula device, with a gas flow rate of 20-35 liters per minute or as high as the patient will tolerate and an FiO2 to keep SaO2 ≥ 90% (Airvo 2, Fisher and Paykel Healthcare). Gas flow temperature will be adjusted based on patient's comfort and range from 34-37 degrees centigrade. After completion of the study, patients will be switched back to oxygen therapy administered by nasal prongs or mask.

This is a pilot study in which the primary outcome is to determine the level of comfort experienced by the patient of using high-flow nasal oxygen administered by two different nasal cannulas. It is not an efficacy trial and there is no formal power analysis. All subjects are randomly assigned to two sequences, and each subject is treated subsequently with two treatments, the order of the treatments depends on its sequence. Initially, the primary endpoint and secondary endpoints will be evaluated for a carryover effect, a period effect, and a treatment effect with the use of two-tailed t-tests. We will then model treatment effects, period effects, and carryover effects using the linear mixed-effects model for this 2x2 crossover study.

Subjects may discontinue participation in the study at any point and for any reason. This decision will not be held against them in any way. If a subject decides to withdraw, the physician will assess their clinical condition and determine the best course of action for the subject. This may include alternative methods of oxygen administration. Any data that is collected up to the point of subject withdrawal will be retained for analysis.

Risks to Subjects

The AIRVO 2 is an FDA cleared device (510k number K131895). There are few expected side effects of using the AIRVO 2 device - if the humidification is too low, the subject may experience nasal/throat discomfort or epistaxis. It has been determined to be a non-significant risk device in that it meets none of the criteria for a significant risk device.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Other
盲法
None

入排标准

年龄范围
40 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •i.aged ≥ 40 years (ii) hospitalization for acute exacerbation of COPD; (iii) smoker or ex-smoker (iv) FEV1 <80% of predicted and FEV1/FVC <70% postbronchodilator within 12 months prior to admission (v) have no other lung disease (including asthma) as a principal cause of pulmonary function limitation (vi) baseline PaCO2 ≥ 45 mm Hg at study entry. (vii) willing to give informed consent (viii) willing to participate in measurement of ABGs (ix) will to provide a brief history and physical examination and answer questionnaires.

排除标准

  • •Adults unable to consent
  • •Individuals who are not yet adults (infants, children, teenagers)
  • •Women who are known to be pregnant at the time of hospital admission
  • •Prisoners
  • •Individuals who do not understand English

研究组 & 干预措施

Conventional symmetric nasal cannula

Active Comparator

The patient's breathing pattern will be assessed by inductive plethysmography while using the cannula and receive HFNT for 2 hours during the first session. Patients will then be randomized to use of the conventional symmetric nasal cannula or the new asymmetric nasal cannula. At the end of the first session questionnaire data will be collected and ABGs will be repeated followed by a 30-minute rest period without any device. Patients will then crossover to receive HFNT via the other cannula type for another 2 hours during the second session. Inductive plethysmography will again be worn and ABGs will be obtained, and questionnaires will again be administered

干预措施: AIRVO 2, the new asymmetric nasal cannula (Device)

AIRVO 2; new asymmetric nasal cannula

Active Comparator

The patient's breathing pattern will be assessed by inductive plethysmography while using the cannula and receive HFNT for 2 hours during the first session. Patients will then be randomized to use of the conventional symmetric nasal cannula or the new asymmetric nasal cannula. At the end of the first session questionnaire data will be collected and ABGs will be repeated followed by a 30-minute rest period without any device. Patients will then crossover to receive HFNT via the other cannula type for another 2 hours during the second session. Inductive plethysmography will again be worn and ABGs will be obtained, and questionnaires will again be administered

干预措施: AIRVO 2, the new asymmetric nasal cannula (Device)

结局指标

主要结局

Determining the level of comfort experienced by the patient of using high-flow nasal oxygen administered by two different nasal cannulas.

时间窗: 6 hours

This is a pilot study in which the primary outcome is to determine the level of comfort experienced by the patient of using high-flow nasal oxygen administered by two different nasal cannulas. The level of comfort will be assessed by a 100 mm visual analog scale from 0 (no discomfort) to 100 (maximal imaginable discomfort)

Sensation of shortness of breath

时间窗: 6 hours

Likert scale model indicating marked improvement (+2), slight improvement (+1), no change (0), slight deterioration (-1) and marked deterioration (-2) in patient's sensation of shortness of breath and overall comfort

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验