跳至主要内容
临床试验/NCT06444425
NCT06444425Enrolling By Invitation不适用

Korotkoff Sounds Dynamically Reflect Changes in Cardiac Function Based on Deep Learning Methods: A Prospective, Multicenter Study

The Fourth Affiliated Hospital of Zhejiang University School of Medicine1 个研究点 分布在 1 个国家目标入组 685 人开始时间: 2024年6月1日最近更新:
适应症

试验速览

阶段
不适用
状态
Enrolling By Invitation
发起方
入组人数
685
试验地点
1
主要终点
Cardiac Dysfunction

研究概览

简要总结

The Korotkoff Sounds(KS), which have been in use for over a century, are widely regarded as the gold standard for measuring blood pressure. Furthermore, their potential extends beyond diagnosis and treatment of cardiovascular disease; however, research on the KS remains limited. Given the increasing incidence of heart failure (HF), there is a pressing need for a rapid and convenient prehospital screening method. In this study, we propose employing deep learning (DL) techniques to explore the feasibility of utilizing KS methodology in predicting functional changes in cardiac ejection fraction (LVEF) as an indicator of cardiac dysfunction.

详细描述

Blood Pressure Measurement:Around 72 hours before and after the completion of the patient's echocardiogram, considering the variability in the patient's blood pressure and ejection fraction at different times, blood pressure should be measured in each participant at least twice a day, up to a maximum of six times. Each patient should be instructed to remain in a quiet state for 10 minutes before blood pressure measurement. Blood pressure measurement should be conducted according to the following criteria: the cuff used to measure blood pressure should be wrapped around the patient's arm above the elbow joint, positioned 2-3 cm above the level of the heart, with a snugness that allows one finger to fit underneath. Place the stethoscope head at the brachial artery pulse point on the left elbow joint, then begin inflation. Inflate continuously until the sound of the pulse beat disappears; then inflate an additional 20 mmHg before stopping inflation. Slowly deflate while listening-the first audible pulse beat is the systolic pressure, and the disappearance of the pulse sound is the diastolic pressure. Use the Hanhong POPULAR-3 electronic stethoscope to record the aforementioned process, with each audio recording lasting 25 seconds uniformly.

Data Analysis Overview:

In terms of data analysis, deep learning models are developed based on Torch version 1.5.0, utilizing Transformer network architecture to analyze the collected audio data.

Network One: Identifying the presence of cardiac functional abnormalities through Korotkoff sounds.

Evaluation Metrics: Receiver Operating Characteristic (AUROC), sensitivity, specificity, and F1 score (harmonic mean of sensitivity and specificity) to assess model performance on the test dataset.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Patients who were admitted to the Cardiology Department of the aforementioned four Groups (The Fourth Affiliated Hospital of School of Medicine of Zhejiang University, Zhejiang Taizhou Hospital, Quzhou People's Hospital, Zhejiang Quhua Hospital)between June 2024 and December 2024, and successfully underwent echocardiographic examinations.
  • •Individuals aged between 18 and 90 years with a resting heart rate ranging from 60 to 100 beats per minute.
  • •Demonstrating good compliance, capable of cooperating in completing multiple blood pressure measurements within 72 hours following the completion of echocardiography.
  • •Willingness to voluntarily participate in the study.

排除标准

  • •Patients with acute decompensated heart failure, acute myocardial infarction, atrioventricular block;
  • •Cerebral hemorrhage, severe infection, active digestive tract ulcer, severe hematological diseases, severe liver and kidney dysfunction or other serious medical or surgical conditions;
  • •Pregnant or lactating women;
  • •Patients with mental illness;
  • •Individuals who have participated in other clinical trials within the past 3 months.

结局指标

主要结局

Cardiac Dysfunction

时间窗: Evaluation LVEF:Cardiac ultrasound was performed 72 hours prior to and following anti-Acute Heart Failure treatment.

The pathophysiology of heart failure encompasses a multifaceted clinical syndrome: 1)Cardiac structural and/or functional abnormalities resulting in impaired ventricular diastolic function and/or systolic ejection capacity;2)Corresponding clinical manifestations indicative of heart failure; 3)Typically accompanied by elevated levels of beneficial natriuretic peptide(BNP), as well as pulmonary or systemic congestion suggestive of cardiac origin on imaging studies, or objective evidence of increased ventricular filling pressure on hemodynamic assessments.4)According to the classification of left ventricular ejection fraction (LVEF) based on cardiac ultrasound, heart failure can be categorized into four types: reduced ejection fraction heart failure (HFrEF), improving ejection fraction heart failure (HFimpEF), moderately reduced ejection fraction heart failure (HFmrEF), and retained ejection fraction heart failure (HFpEF).

次要结局

未报告次要终点

研究者

发起方
The Fourth Affiliated Hospital of Zhejiang University School of Medicine
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验