跳至主要内容
临床试验/NCT03120546
NCT03120546已完成不适用

A Randomized Comparison of Cervical Spine Motion During Tracheal Intubation Using Video Laryngoscope or Rigid Video Stylet in Patients With Simulated Cervical Immobilization

Seoul National University Hospital1 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2017年7月25日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
22
试验地点
1
主要终点
maximum cervical spine motion

研究概览

简要总结

In this study, investigators are going to compare cervical spine motion during tracheal intubation using video laryngoscope or rigid video stylet in patients with simulated cervical immobilization.

详细描述

In patients with an unstable cervical spine, neck extension during tracheal intubation may result in harmful events such as spinal cord injury. Thus, it is important to minimize cervical spine motion in these patients. In this randomized crossover study, investigators are going to compare cervical spine motion during tracheal intubation using video laryngoscope or rigid video stylet in patients with simulated cervical immobilization.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Other
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients aged 18-80 years undergoing elective endovascular cerebral aneurysm coiling to general anesthesia in a neuroangiography suite

排除标准

  • Patients with upper airway abnormalities such as inflammation, abscesses, tumors, polyps, and trauma
  • Patients with a medical history of gastroesophageal reflux disease and previous airway surgery, at high risk for aspiration, coagulation disorders, or a Hunt Hess grade of 3-5

研究组 & 干预措施

Group A

Experimental

rigid video stylet intubation - video laryngoscope intubation

干预措施: rigid video stylet intubation (Device)

Group A

Experimental

rigid video stylet intubation - video laryngoscope intubation

干预措施: video laryngoscope intubation (Device)

Group B

Experimental

video laryngoscope intubation - rigid video stylet intubation

干预措施: rigid video stylet intubation (Device)

Group B

Experimental

video laryngoscope intubation - rigid video stylet intubation

干预措施: video laryngoscope intubation (Device)

结局指标

主要结局

maximum cervical spine motion

时间窗: during tracheal intubation

maximum angles measured at the occiput-C1, C1-C2, C2-C5 segments

次要结局

  • number of intubation trial(during tracheal intubation)
  • intubation time(during tracheal intubation)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Tae Kyong Kim

Clinical Assistant Professor

Seoul National University Hospital

研究点 (1)

Loading locations...

相似试验