跳至主要内容
临床试验/NCT01717001
NCT01717001已完成不适用

In Vivo Determination & Comparison of Knee Kinematics for Subjects Implanted With Either a Personalized ConforMIS or Traditional Knee Implant

Restor3D2 个研究点 分布在 1 个国家目标入组 66 人开始时间: 2012年8月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
66
试验地点
2
主要终点
Post-operative Range of Motion

研究概览

简要总结

A better understanding of knee joint kinematics is important to explain the premature polyethylene wear failures within total knee arthroplasties (TKAs) and to help design a prosthesis that most closely approximates the normal knee. Previously, most experimental studies of knee kinematics have involved cadaveric, in vitro analyses, or have not tested the knee in a weight-bearing mode. Others have used exoskeletal linkages and skin markers that permit error due to undesired motions between markers and the underlying bone. More recently, fluoroscopy has been used to assess in vivo kinematics for subjects having a TKA.

ConforMIS has attempted to follow a clearly different path than the major orthopaedic companies. They have chosen to offer patients a personalized knee implant based off of each patient's femoral and tibial bone geometry. The hypothesis is that these subjects will experience a more normal-like kinematic pattern, eliminating paradoxical anterior sliding during weight-bearing knee flexion. Therefore, the objective for this study is to analyze the in vivo kinematics for 25 patients implanted with a personalized ConforMIS TKA and 25 patients implanted with a traditional TKA design to determine if there are any kinematic differences between these TKA designs.

详细描述

Each subject will be asked to perform five activities in one continuous sequence: (1) stand up from a chair, (2) walk up stairs, (3) walk down stairs, (4) level walking, and (5) a deep knee bend. Subjects will be video recorded from the waist down while performing the activities. The speed level of each trial will be based on the comfort level of the patient. The fluoroscopic images will be stored digitally for subsequent analysis on secure servers and workstations at the University of Tennessee.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
40 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • At least 6 months post-op with no other surgical procedures conducted within the past 6 months
  • Between 40-70 years of age
  • Body weight of less than 250lbs
  • BMI of less than 38
  • Pregnant females will be excluded
  • TKA patients will be judged Clinically successful with an American Knee Society score of greater than 90
  • Must have 100 degrees post-op passive flexion with no ligamentous laxity or pain
  • Participants must be able to walk on level ground without aid of any kind and ascend/descend stairs without assistance.
  • All potential subjects will have either a personalized ConforMIS™ TKA or a traditional TKA manufactured by an orthopaedic company other than ConforMIS.
  • Patients from the physician's list who do not meet the study requirements will not be considered.
  • Patients must be willing to sign the Informed Consent and HIPAA forms to participate in the study.
  • Patients must be between 160cm (5'3) and 193cm (6'4) tall.

排除标准

  • 未提供

结局指标

主要结局

Post-operative Range of Motion

时间窗: at least 6 months post-surgery

Comparison of amount of flexion achieved by the knee between the two arms

次要结局

未报告次要终点

研究者

发起方
Restor3D
申办方类型
Industry
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验