跳至主要内容
临床试验/NCT02613338
NCT02613338已完成不适用

Kinematic Analysis: Posterior Stabilized, Fixed Bearing Total Knee Arthroplasty With Attune Knee System - Phase 2

The University of Tennessee, Knoxville5 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2015年11月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
30
试验地点
5
主要终点
Femoro-tibial Kinematics - Lateral Anterior/Posterior Motion

研究概览

简要总结

A better understanding of knee joint kinematics is important to explain the premature polyethylene wear failures within total knee arthroplasties (TKAs) and to help design a prosthesis that most closely approximates the normal knee. Specifically, posterior stabilizing (PS) knees have been found to be associated with lower amounts of posterior femoral rollback, higher occurrence of reverse axial rotation and increased amount of condylar lift-off. The DePuy Synthes Joint Reconstruction's Attune PS fixed bearing (FB) knee system has incorporated subtle changes in its design to address restoration of kinematics that more closely resemble those of a normal knee. To understand if this design is able to effectively restore kinematics in the implanted knee, further in vivo analysis is necessary. This continuation of the study will analyze 30 subjects with the Attune PS FB 3 months post-operatively using the University of Tennessee's mobile fluoroscopy unit while performing three daily activities, level walking, ramp down and deep knee bend.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Cross Sectional

入排标准

年龄范围
30 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • At least three (3) months post-operative with no other surgical procedures conducted within the past six months
  • Between 30-80 years of age
  • Body weight of less than 280 lbs
  • Must be between 160cm (5'3) and 193cm (6'4) tall
  • Body Mass Index (BMI) >18.5 and <35
  • Judged clinically successful with a Knee Society score (KSS) of greater than 80
  • Have good-to-excellent post-operative passive flexion with no ligamentous laxity or pain
  • Must be able to walk on level ground without aid of any kind, perform a ramp descent, and a deep knee bend (DKB), all without assistance
  • Will have a DePuy Attune PS TKA

排除标准

  • Pregnant or potentially pregnant females will be excluded from the study.

结局指标

主要结局

Femoro-tibial Kinematics - Lateral Anterior/Posterior Motion

时间窗: 3 months post-operative

Amount of anterior sliding (positive) and/or posterior rollback (negative) of the lateral condyle during DKB, gait, and ramp down

Femoro-tibial Kinematics - Medial Anterior/Posterior Motion

时间窗: 3 months post-operative

Amount of anterior sliding (positive) and/or posterior rollback (negative) of the medial condyle during DKB, gait, and ramp down

Femoro-tibial Kinematics - Axial Rotation

时间窗: 3 months post-operative

Amount of axial rotation of the femoral component with respect to the tibial component during DKB, gait, and ramp down. Positive indicated external rotation of femur wrt tibia.

Femoro-tibial Kinematics - Weight-bearing Flexion

时间窗: 3 months post-operative

Amount of weight-bearing flexion during DKB, gait, and ramp down. All numbers are positive, indicating magnitude.

次要结局

  • Max Ground Reaction Force - Ramp Down(3 months post-operative)
  • Max Ground Reaction Force - Deep Knee Bend(3 months post-operative)
  • Max Ground Reaction Force - Gait(3 months post-operative)

研究者

发起方
The University of Tennessee, Knoxville
申办方类型
Other
责任方
Principal Investigator
主要研究者

Richard Komistek

Fred M. Roddy Professor of Biomedical Engineering

The University of Tennessee, Knoxville

研究点 (5)

Loading locations...

相似试验

Kinematic Analysis: Posterior Stabilized, Fixed... | 临床试验