MedPath

Low Workload Concept for the Detection of Silent Atrial Fibrillation (AF) and Atrial Fibrillation Burden in Patients at High Risk of AF and Stroke

Not Applicable
Active, not recruiting
Conditions
Atrial Fibrillation
Cardiovascular Diseases
Pathologic Processes
Postoperative Complications
Arrhythmias, Cardiac
Heart Diseases
Interventions
Device: Smartphone application
Device: Bed sensor
Device: Wrist-worn photoplethysmography (PPG) and accelerometer data logger.
Device: Patch-holter ECG
Registration Number
NCT05351775
Lead Sponsor
University of Turku
Brief Summary

Patient-centered novel e-health technology and services will lay the foundation for future healthcare systems and services to support health and welfare promotion. Yet, there is a lack of ways to incorporate novel technological innovations into easy-to-use, cost-effective and low workload treatment.

The detection of atrial fibrillation (AF) paroxysms and its permanent form as well as the prevention of AF-related strokes are major challenges in cardiology today. AF is often silent or asymptomatic, but the risk of ischemic stroke seems to be similar regardless of the presence or absence of symptoms.

CARE-DETECT algorithm development part I will investigate following topics:

1. The usefulness and validity of bed sensor and mobile phone application in rhythm disorder capture compared to gold standard ECG-holter monitoring (Faros ECG)

2. Accuracy of AF detection from PDL data

3. Technical development of algorithms to detect arrhythmia from data collected with these novel devices

4. Development of a pre-processing tool that will evaluate the collected data and generate a preliminary filtered report of the raw data to ease clinician's workload in data handling and rhythm evaluation.

CARE-DETECT clinical trial (part II) proposal provides a new concept for low workload for healthcare personnel, high diagnostic yield in silent AF detection and AF burden evaluation. CARE-DETECT protocol proposal seeks to address following issues:

1. Can a combination of actively used smartphone application and passive monitoring with bed sensor (with upstream ECG) - compared to routine care - enhance the detection of AF in patients who are at increased risk of stroke and have undergone a cardiac procedure?

2. What is the actual AF burden in paroxysmal AF patients after the detection of new-onset AF?

3. Can a direct-to-consumer telehealth with integrated cloud-based telecardiology service for medical professionals improve the efficacy of silent AF detection and what is the AF burden in patients suffering of (asymptomatic) paroxysmal AF and secondarily what is the cost-effectiveness of these new screening methods?

4. Additionally, during the hospitalization phase of the study part II PDL data will be collected in the intervention group. PDL data will be analyzed offline with the purpose to develop new methods and will not be used to monitor treatment or for diagnosis.

Detailed Description

The detection of atrial fibrillation (AF) paroxysms and its permanent form as well as the prevention of AF-related strokes are major challenges in cardiology today. AF is often silent or asymptomatic, but the risk of ischemic stroke seems to be similar regardless of the presence or absence of symptoms. Asymptomatic AF patients are more likely to evade diagnostic effort and without appropriate anticoagulation they are left vulnerable to thromboembolism and ischemic stroke. Approximately one third of all ischemic strokes are of an unknown cause. Recent studies have shown that more diligent monitoring of heart rhythm with ambulatory devices after a cryptogenic stroke uncovers a high number of silent AF episodes. Timely detection of silent AF is challenging and, therefore, a stroke is still too often the first clinical manifestation of AF accounting for 22% of AF-related strokes. In order to detect symptoms appearing at periodic or random intervals, a capability for longer-term monitoring, e.g. for several days or weeks at a time, is required. Implantable electrocardiogram (ECG) loop recorders perform well in AF detection, but they are hardly feasible in large patient cohorts due to invasive nature and costs. Thus, there is an unmet clinical need for better AF detection tools.

During the Automated Detection of Atrial Fibrillation via a Miniature Accelerometer and Gyroscope (NoStroke) project (as well as other projects carried out simultaneously at Department of Future Technologies, University of Turku, mainly funded by Tekes) a smartphone application has been developed for the detection of AF, which is implemented as a stand-alone solution to a common smartphone. The application utilizes the inbuilt motion sensors of the smartphones without any need to external sensors or equipment, such as electrodes or wires. This application (CardioSignal app) is a CE-marked medical device and will be used in this project and it will provide a venue for a clinical showcase of the application and more importantly, validate whether the application would be beneficial in the clinical settings in this follow-up study.

Bed sensor (Emfit ltd) is a CE-marked device. It is based on ballistography method where a heartbeat-induced recoil can be measured while the subject is lying on the bed. Electromechanical membrane sensor recognizes and registers the recoil, and subsequently, this data can be used to assess heart rate and other relevant vital function. Philips Data Logger (PDL) measures continuously photoplethysmogram (PPG) and accelerometer data from the top side of the wrist using green wavelength Light Emitting Diode (LED) and 3-axis accelerometer. Faros Holter-monitor measures single-lead ECG signal from the chest and is attached via FastFix electrode.

The part I trial is open, prospective interventional trial. These recordings are used merely to technical testing, validity evaluation and algorithm development purposes and the data is not used in any clinical evaluation whatsoever.

The part II is a prospective, randomized, open-label, interventional study. Upon receipt of the signed written informed consent and satisfactory documentation that the patient met all inclusion and had no exclusion criteria, the study subjects will be randomized to either intervention or control arm. The randomization allocation will take into account the procedure subgroup of the patient (open-heart surgery, aortic valve replacement and transcatheter aortic valve implantation (TAVI) or coronary bypass and percutaneous coronary intervention (PCI)). In both subgroups the randomization will be done 1:1. Patients will be randomized before hospital discharge.

The number of study subjects needed was estimated to be 300. Complying with the original plan, interim analysis was performed when 100 cases were enrolled. Based on the interim analysis results, the target enrollment number of patients was reduced to 150 patients due to the high number of false positive alerts leading to high-workload protocol inadequate for clinical use as such.

Recruitment & Eligibility

Status
ACTIVE_NOT_RECRUITING
Sex
All
Target Recruitment
150
Inclusion Criteria
  • One of listed cardiac operation performed during the index hospitalization:

    1. open heart surgery (aortic valve replacement (AVR), coronary artery bypass graft (CABG) or combination treatment) or
    2. percutaneous intervention (transcatheter aortic valve implantation (TAVI) or percutaneous coronary intervention (PCI))
  • Patient has been informed on the nature of the study, agrees to its provisions and has provided written informed consent approved by the appropriate Medical Ethics committee.

  • In PCI group, the randomization may take place after operation

  • Age ≥18 years

  • CHA2DS2VASC score ≥ 4, or CHA2DS2VASC score ≥ 2 and at least one of the following: ECG P wave duration ≥ 120 ms, left atrial diameter > 38 mm in women or > 40 mm in men, renal impairment (eGFR < 50 ml/min), age ≥ 70 years, active smoking

  • Anticipated life expectancy 12 months or more

  • Patient is capable of using the study application and bed sensor

  • Patient is willing to comply with study specific follow-up evaluations and home-based monitoring

Read More
Exclusion Criteria
  • Age < 18 years
  • Expected survival < 1 year
  • Permanent anticoagulation therapy due to atrial fibrillation
  • Patient lives outside the catchment area
  • Any significant medical condition, which in the Investigator's opinion may interfere with the patient's optimal participation in the study.
Read More

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Interventional AF detection armPatch-holter ECGThe patients will be monitored during index hospitalization according normal practice and additionally with a bed sensor, smartphone app, and patch-holter ECG. In addition, patients will have PDL monitoring device during hospitalization. During the index hospitalization, patients will download the CardioSignal app to their own smartphone or if patient does not have a smartphone one can be provided to the patient by the study group. Patients are asked to do the first recordings at hospital to test the device and then preferably twice daily for 1 minute period of time during the 3-month study period. When discharged home, the study subject will have the bed sensor for home-based use up to 3 months. If the average pulse rate in the bed sensor recordings have increased with 20% or the device has recorded rhythm irregularity lasting over 5 minutes (could be longer to reduce false alarms), a 12-lead ECG will be taken, and in the case of a normal ECG, a 7-day Holter monitoring is performed.
Interventional AF detection armSmartphone applicationThe patients will be monitored during index hospitalization according normal practice and additionally with a bed sensor, smartphone app, and patch-holter ECG. In addition, patients will have PDL monitoring device during hospitalization. During the index hospitalization, patients will download the CardioSignal app to their own smartphone or if patient does not have a smartphone one can be provided to the patient by the study group. Patients are asked to do the first recordings at hospital to test the device and then preferably twice daily for 1 minute period of time during the 3-month study period. When discharged home, the study subject will have the bed sensor for home-based use up to 3 months. If the average pulse rate in the bed sensor recordings have increased with 20% or the device has recorded rhythm irregularity lasting over 5 minutes (could be longer to reduce false alarms), a 12-lead ECG will be taken, and in the case of a normal ECG, a 7-day Holter monitoring is performed.
Interventional AF detection armBed sensorThe patients will be monitored during index hospitalization according normal practice and additionally with a bed sensor, smartphone app, and patch-holter ECG. In addition, patients will have PDL monitoring device during hospitalization. During the index hospitalization, patients will download the CardioSignal app to their own smartphone or if patient does not have a smartphone one can be provided to the patient by the study group. Patients are asked to do the first recordings at hospital to test the device and then preferably twice daily for 1 minute period of time during the 3-month study period. When discharged home, the study subject will have the bed sensor for home-based use up to 3 months. If the average pulse rate in the bed sensor recordings have increased with 20% or the device has recorded rhythm irregularity lasting over 5 minutes (could be longer to reduce false alarms), a 12-lead ECG will be taken, and in the case of a normal ECG, a 7-day Holter monitoring is performed.
Interventional AF detection armWrist-worn photoplethysmography (PPG) and accelerometer data logger.The patients will be monitored during index hospitalization according normal practice and additionally with a bed sensor, smartphone app, and patch-holter ECG. In addition, patients will have PDL monitoring device during hospitalization. During the index hospitalization, patients will download the CardioSignal app to their own smartphone or if patient does not have a smartphone one can be provided to the patient by the study group. Patients are asked to do the first recordings at hospital to test the device and then preferably twice daily for 1 minute period of time during the 3-month study period. When discharged home, the study subject will have the bed sensor for home-based use up to 3 months. If the average pulse rate in the bed sensor recordings have increased with 20% or the device has recorded rhythm irregularity lasting over 5 minutes (could be longer to reduce false alarms), a 12-lead ECG will be taken, and in the case of a normal ECG, a 7-day Holter monitoring is performed.
Primary Outcome Measures
NameTimeMethod
The rate of new AF burden during index hospitalization.During hospital stay (assessed up to 10 days).

AF defined by 12-lead ECG or ECG-holter adjudicated by a cardiologist and in borderline cases by two independent cardiologists.

Algorithm development.The part I trial during index hospitalization (assessed up to 48 hours). The part I trial with PDL may be continued among the part II interventional group during initial hospitalization (assessed up to 10 days) in order to collect additional data.

The gold standard reference (ECG or Holter) data will be collected to develop an algorithm to detect AF from PPG data.

The rate of new AF burden during 3 months follow-up after index hospitalization.During 3 months follow-up.

AF defined by 12-lead ECG or ECG-holter adjudicated by a cardiologist and in borderline cases by two independent cardiologists.

Number of technical issues of the concept and interface.The part I trial during index hospitalization (assessed up to 48 hours).

In part I study the bed sensor technology and mobile phone application will be tested and validated in an open set-up to reliability of the devices and applications before starting the randomized part II of the trial.

The rate of new AF during index hospitalization.During hospital stay (assessed up to 10 days).

AF defined by 12-lead ECG or ECG-holter adjudicated by a cardiologist and in borderline cases by two independent cardiologists.

The rate of new AF during 3 months follow-up after index hospitalization.During 3 months follow-up.

AF defined by 12-lead ECG or ECG-holter adjudicated by a cardiologist and in borderline cases by two independent cardiologists.

Number of practical issues of the concept and interface.The part I trial during index hospitalization (assessed up to 48 hours).

In part I study the bed sensor technology and mobile phone application will be tested and validated in an open set-up to usability of the devices and applications before starting the randomized part II of the trial.

Number of adverse events related to PDL device.The part I trial during index hospitalization (assessed up to 48 hours). The part I trial with PDL may be continued among the part II interventional group during initial hospitalization (assessed up to 10 days) in order to collect additional data.

Although the PDL is safe to use, the user may experience adverse reactions. This is due to wearing the device in contact with the skin for long periods at a time. These reactions include: skin reactions due to pressure of the device on the skin or the device rubbing against the skin, skin reactions due to dirt or moisture in between the device and the skin, skin irritation due to the materials used (colored acrylonitrile butadiene styrene (ABS) and thermoplastic polyurethane (TPU)).

Secondary Outcome Measures
NameTimeMethod
All-cause mortality.During 12 months follow-up.

Postoperative death from any cause. All-cause mortality will be derived from the hospital electronical medical records and The National Causes of Death Register.

Additional costs per detected case of new AF.During 12 months follow-up.

The cost-effectiveness (cost/new AF detected) of a direct-to-consumer telehealth with integrated cloud-based telecardiology service for medical professionals in the silent AF detection and in the AF burden screening. Control group has no additional cost because no screening is performed. Intervention group costs consist of device (bedsensor) cost, monthly app fee (smartphone) and cloud server fee. Additionally time and salary of the healthcare professionals (hours) related to work of device alerts.

Number of participants adherent to anticoagulant treatment.During 12 months follow-up.

In the patients who receive oral anticoagulant (OAC) prescription, the rate of anticoagulant therapy adherence will be confirmed using a comparison of the medication prescribed at hospital discharge (data in the prescription database) to that derived from the the Drug Reimbursement Register. If patient has not purchased medication, no entry in the Drug Reimbursement Register is seen.

Number of Participants with Stroke, TIA and peripheral embolism.During 12 months follow-up.

Stroke is defined as a permanent focal neurological deficit adjudicated by a neurologist, and confirmed by computed tomography or magnetic resonance imaging. Transient ischemic attack (TIA) is defined as a transient (\<24 hours) focal neurological deficit adjudicated by a neurologist. Peripheral embolism refers to peripheral arterial embolism during follow-up.

Trial Locations

Locations (1)

Heart Center, Turku University Hospital

🇫🇮

Turku, Finland