RF Lesion Monitoring With 8mm IntellaTip MiFi XP

Completed
Conditions
Arrhythmia
Atrial Flutter
Interventions
Device: Catheter ablation
Registration Number
NCT02089672
Lead Sponsor
Emory University
Brief Summary

Abnormal heart rhythms or arrhythmias are often managed by a procedure in which a catheter is introduced into the heart. These catheters can then cauterize abnormally functioning portions of the heart muscle with the hope of returning the heart to a more effective rhythm. In the process of performing such a procedure, called a catheter ablation, an operator must be able to accurately sense electrical activity displayed on computer screens in different parts of the heart, provide sufficient localized energy to the abnormally behaving tissue (ideally without damaging uninvolved heart structures), and accurately reassess the electrical activity of the heart to ensure the spot in the heart has been cauterized.

When sensing electrical activity of the heart, specialized catheters produce recordings on a computer screen known as electrograms (EGM). To produce this recording conventional catheters commonly use a positive and negative electrode, from which the difference between the two provides the EGM. The distance between the two electrodes varies from device to device. The greater the distance between them, the less accurate the measurement of local electrical activity becomes. This may result in poorly localized or excessive use of energy that could be damaging to normal heart structures or put the patient at risk for the return or development of additional arrhythmias. The IntellaTip MiFi catheter has been constructed with a specialized sensing tip that uses "microelectrodes" that are relatively close in proximity (\<1 mm apart) with the hope of improving the sensing capability of the device.

This study will analyze the signals obtained from this FDA-approved catheter in people undergoing a catheter ablation procedure. The study will examine signals after the procedure is finished and will not prolong or differ the process from a standard ablation procedure. The goal of this study is to determine the ability of the microelectrodes to distinguish ablated, or cauterized versus non-cauterized tissue.

Detailed Description

This trial is an operator-blinded, acute, single-visit observational trial in humans. Enrollment will include 25 patients undergoing a radiofrequency ablation procedure in which ablation of the cavotricuspid isthmus is planned. Electrogram characteristics of the small, imbedded pin electrodes will be compared to standard bipolar EGMs utilizing the ablation tip electrode and ring. Absolute voltage, voltage reduction, and frequency spectra will be examined before, during, and after ablation. EGM characteristics of standard and "ultra-local" recordings will be compared in their ability to accurately identify an effective RF lesion as defined below.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
30
Inclusion Criteria
  • Any adult undergoing an atrial flutter ablation
Read More
Exclusion Criteria
Read More

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Atrial flutter patientsCatheter ablationAtrial flutter patients undergoing catheter ablation
Primary Outcome Measures
NameTimeMethod
Total bipolar electrogram amplitude using tip to ring and pin to pin configurationsAcute, averaged one hour during ablation. Measured postoperatively.
Secondary Outcome Measures
NameTimeMethod
Total number of seconds per isthmus ablation spent in excess of the post-hoc identified complete lesion time.Acute, averaged one hour during ablation. Measured postoperatively

Trial Locations

Locations (1)

Emory University Hospital

🇺🇸

Atlanta, Georgia, United States