MedPath

Dose Reduction and Acquisition Parameters Optimization for PEDiatric Digital Radiography

Conditions
Pediatric Radiology
Registration Number
NCT04007627
Lead Sponsor
Assistance Publique - Hôpitaux de Paris
Brief Summary

To reduce "As Low As Diagnostically Acceptable" (ALADA) the X ray exposure of pediatric radiology by using a new post treatment processing algorithm (S-Vue, Samsung table GC85A).

Detailed Description

The study will investigate the minimum dose required to obtain acceptable image quality for different pediatric localizations (abdomen, thorax, pelvis, spine) by using a simulation tool of different dose levels. Three different radiologists blinded to the simulated dose level will score the images independently by using a dedicated image quality scoring grid.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
200
Inclusion Criteria
  • Children aged under 18 years and under 80 kg;
  • Prior radiography perfomed within 6 months before the beginning of the study.
Exclusion Criteria
  • Refusal of parents to participate to the study.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Assesment of image quality by radiologists blinded to the simulated dose levelthrough study completion, an average of 6 months

Three different radiologists will score the images of localizations of abdomen, thorax, pelvis, spine independently by using a dedicated image quality scoring grid.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Service de Radiologie Pédiatrique, C.H.U. Bicêtre, APHP

🇫🇷

Le Kremlin-Bicêtre, Île De France, France