Comparison of Breathing Pattern During Neurally Adjusted Ventilatory Assist Ventilation and Pressure Support Ventilation

Not Applicable
Completed
Conditions
Respiratory System Abnormalities
Interventions
Device: Servo-i® ventilator, MAQUET,Critical Care, Sweden
Registration Number
NCT01614873
Lead Sponsor
Centre d'Investigation Clinique et Technologique 805
Brief Summary

Comparison of Breathing pattern during mechanical ventilation. Two modes of mechanical ventilation are compared (Pressure Support Ventilation and Neurally Adjusted Ventilatory Assist)

Detailed Description

Eligibility : healthy subject without respiratory complications in the past

Subjects will breath spontaneously without mechanical ventilation, with Pressure Support Ventilation and with Neurally Adjusted Ventilatory Assist during.

Three levels of pressurisation will be tested : 5 cmH2O, 8 cmH2O and 12 cmH2O Duration of each condition will be about 15 minutes.

Measurements will include:Flow, airway pressure, SaO2, PtCO2, diaphragmatic electromyography, chest wall motion by optoelectronic plethysmography

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
10
Inclusion Criteria
  • Age > 18 years
  • Healthy Subject without any chronic disease
Exclusion Criteria
  • Absence of consent
  • Pregnant

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Pressure Support VentilatorServo-i® ventilator, MAQUET,Critical Care, SwedenGold standard partial ventilator support: Pressure Support Ventilation performed with Servo-i® ventilator (MAQUET,Critical Care, Sweden). During pressure support the inspiratory muscles are assisted by a constant inspiratory pressure adjusted by the prescriptor and applied to the airway by either an invasive or a non invasive interface. Then the subject initiate the inspiratory effort and a constant pressure is delivered to the airway in order to assist inspiration. Three levels of pressure will be tested (5 cmH2O, 8 cmH2O and 12 cmH2O)
NAVAServo-i® ventilator, MAQUET,Critical Care, SwedenSpontaneous Breathing using Neurally Adjusted Ventilatory Assist with trigger adjusted on diaphragmatic electromyogram. Electrical activity of the diaphragm will be obtained through a naso-gastric tube with multiple array of electrodes placed at its distal end (Eadi catheter® , Maquet Critical Care, Sweden). During NAVA the inspiratory muscles are assisted by a pressure which is proportional to this electrical activity. Then the subject initiate the inspiratory effort and a pressure proportional to the integrated EMG activity is delivered to the airway in order to assist inspiration. The adjustment of the level of NAVA (expressed in cmH2O/microvolt) will be adjusted in order to obtain a peak pressure similar to pressure support (5 cmH2O, 8 cmH2O and 12 cmH2O)
Primary Outcome Measures
NameTimeMethod
Comparison of breathing pattern during pressure support and Neurally Adjusted Ventilatory Assist (NAVA)2h
Secondary Outcome Measures
NameTimeMethod
Tidal volume evaluated by optoelectronic plethysmography2h
Electrical diaphragmatic activity recorded by mechanical ventilator2h