MedPath

An Evidence Based Protocol for Oxytocin Administration in Vaginal Delivery

Phase 4
Withdrawn
Conditions
Uterine Atony
Postpartum Hemorrhage
Interventions
Registration Number
NCT02410655
Lead Sponsor
NYU Langone Health
Brief Summary

The purpose of this study will be to evaluate a standardized, evidence-based protocol versus a conventional approach for the dosing of oxytocin in vaginal delivery.

Detailed Description

A traditional practice in many US hospitals includes use of 10-40 IU of Oxytocin mixed in various volumes of crystalloid administered at an unspecified and uncontrolled rate (quite often off the pump) in order to restore uterine tone and minimize routine blood loss in the third stage of labor. Many practitioners question high dose oxytocin regimens, timing and duration of Oxytocin administration for postpartum hemorrhage prophylaxis. Given the lack of a universally accepted, evidence based protocol, this study aims at comparing the efficacy of a traditional approach of administration of Oxytocin with an evidence-based designed algorithm.

Recruitment & Eligibility

Status
WITHDRAWN
Sex
Female
Target Recruitment
Not specified
Inclusion Criteria
  • Vaginal Delivery
Exclusion Criteria
  • Cesarean Delivery
  • Allergy to Oxytocin
  • Cardiac Arrhythmia

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Conventional standard of careOxytocinTraditional administration of oxytocin at Lutheran Medical Center involves the use of two 20 IU / 1000 mL bags hung sequentially at a flow rate of 125 mL / hour each after the delivery of the anterior shoulder. This will total no more than 16 hours.
Evidence based protocolOxytocinThe proposed evidence based protocol involves utilizing a single 30IU / 500mL bag of oxytocin. After the delivery of the anterior shoulder, an initial rapid infusion bolus of 50mL of the 30IU / 500mL at 999mL / hour. Three minutes after rapid infusion, uterine tone should be assessed. If inadequate uterine tone persists, a second rapid infusion at the same dose and rate as above should be given. If inadequate uterine tone persists, a third rapid infusion may be given. If adequate uterine tone is achieved after any rapid infusion, the remainder of the bag should be administered at a rate of 100mL / hour until finished. If adequate tone is not achieved, the remainder of the bag should be administered at 100mL / hour and additional uterotonic agents should be considered.
Primary Outcome Measures
NameTimeMethod
Estimated blood loss24 hours postpartum
Secondary Outcome Measures
NameTimeMethod
© Copyright 2025. All Rights Reserved by MedPath