MedPath

Quantitative Susceptibility Mapping (QSM) to Guide Iron Chelating Therapy

Recruiting
Conditions
MRI Scans
Interventions
Radiation: Quantitative Susceptibility Mapping (QSM) Magnetic Resonance Imaging (MRI)
Radiation: R2* Magnetic Resonance Imaging (MRI)
Registration Number
NCT04171635
Lead Sponsor
Weill Medical College of Cornell University
Brief Summary

The overall goal of this research is to help develop a new magnetic resonance (MR) method, Quantitative Susceptibility Mapping (QSM), to improve the measurement of liver iron concentrations without the need for a liver biopsy. Measurement of liver iron is important to diagnose and treat patients who have too much iron in their bodies (iron overload). Liver iron measurements by current MRI methods (R2 and R2\*) can be inaccurate because of the effects of fat, fibrosis and other abnormalities. QSM should not be affected by these factors and should be free of these errors. In this study, MRI measurements (QSM, R2 and R2\*) of iron in patients before liver transplant will be compared with chemical analysis of iron in liver explants (livers removed from patients undergoing liver transplant). The liver explants would otherwise be discarded. Investigators expect that this study will show that the new MRI method, QSM, is superior to the current MRI methods, R2 and R2\*.

Detailed Description

The overall objective of this research is to improve the safety of iron-chelating therapy (ICT) in patients with transfusional iron overload by developing an accurate non-invasive measurement of the liver iron concentration (LIC), the best measure of the body iron burden in all forms of systemic iron overload. The scientific premise is that quantitative susceptibility mapping (QSM) provides a quantitative biophysical connection to LIC. Safe ICT requires careful adjustment of the iron chelator dose to the body iron burden to optimize iron excretion while avoiding chelator toxicity, including gastrointestinal disorders, audiovisual impairment, neutropenia, arthropathy, growth retardation, and hepatic and renal failure. QSM enables accurate measurement of LIC by overcoming the inherent cellular interference in current R2 (=1/T2) and R2\* (=R2+R2') estimates that lack a well-defined biophysical connection to the LIC. A fundamental biophysical limitation of the R2 and R2\* approaches is that intravoxel contents other than iron, including fibrosis, steatosis and necroinflammation, also alter relaxation. In the liver, paramagnetic iron stored in ferritin and hemosiderin is the dominant susceptibility source for QSM. Consequently, magnetic susceptibility measured by QSM has a simple linear relationship with the concentration of iron in the liver and is little affected by fibrosis, steatosis and necroinflammation. The investigator's research plan has 3 specific aims:

Aim 1. Develop hQSM for accurate measurement of LIC without interfering errors. Investigators will optimize data acquisition and processing for free-breathing navigator acquisition with robust fat-water separation.

Aim 2. Validate hQSM using histology and chemical measurement of LIC in liver explants. Investigators will assess the accuracies of LICs measured by hQSM and R2\* in patients before liver transplant with histologic examination using the reference standard of chemical measurement of LIC in liver explants.

Aim 3. Evaluate hQSM in patients with transfusional iron overload under ICT. In patients regularly transfused for thalassemia major, investigators will conduct a double-blind clinical study comparing the accuracy of hQSM and R2\* in measuring annual changes in LIC, using regression against the year-long amount of iron administered in red blood cell transfusions and the year-long cumulative dose of iron chelator.

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
42
Inclusion Criteria
  • Established diagnosis of thalassemia major
  • Treatment with deferasirox formulated as Jadenu® as the sole iron chelating therapy (ICT)
  • Regular transfusion with records maintained in the Cornell Thalassemia Program
  • 2 years of age or older
  • Females who are not pregnant

Inclusion Criteria (for healthy subjects):

  • Men and women aged 21 years or older
  • Able and willing to give consent
  • No known hematological and liver disease
  • No contraindications for MRI
Exclusion Criteria
  • A history of auditory or ocular toxicity related to ICT
  • A history of poor adherence to prescribed therapy
  • An inability to tolerate MRI examinations
  • Treatment for mental illness
  • Institutionalization or imprisonment

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Patients with transfusional iron overloadR2* Magnetic Resonance Imaging (MRI)The subject population of patients with transfusional iron overload awaiting liver transplant has been chosen because of the clinical indication for MRI examination every three months and the availability of liver explants for analysis after transplant. Explants will receive QSM or R2\* MRI to provide a quantitative biophysical connection to liver iron concentration (LIC).
Healthy subjectsQuantitative Susceptibility Mapping (QSM) Magnetic Resonance Imaging (MRI)Healthy control subjects over the age of 21 with no known hematological or liver disease and no contraindications for MRI
Healthy subjectsR2* Magnetic Resonance Imaging (MRI)Healthy control subjects over the age of 21 with no known hematological or liver disease and no contraindications for MRI
Patients with transfusional iron overloadQuantitative Susceptibility Mapping (QSM) Magnetic Resonance Imaging (MRI)The subject population of patients with transfusional iron overload awaiting liver transplant has been chosen because of the clinical indication for MRI examination every three months and the availability of liver explants for analysis after transplant. Explants will receive QSM or R2\* MRI to provide a quantitative biophysical connection to liver iron concentration (LIC).
Primary Outcome Measures
NameTimeMethod
Demonstration of efficacy of quantitative susceptibility mapping (QSM) MRI in quantifying liver iron concentration (LIC)Five years

Investigators will assess the accuracy of liver iron concentrations measured by QSM in patients before liver transplant with histologic examination using the gold standard chemical measurement of LIC in liver explants.

Secondary Outcome Measures
NameTimeMethod
Steatosis as determined by in vivo hQSM, an MRI post-processing technique that provides quantitative information on iron levelsFive years

Quantitative susceptibility mapping (QSM) is widely used by the imaging research community in applications to detect iron. Tissue can become magnetized in response to a magnetic field, and the extent of magnetization is known as susceptibility, which arises from unpaired electrons in iron or external sources such as contrast agents. QSM permits visualization of the sizes and shapes of iron sources, delivers precise estimates of iron concentrations (units: parts per billion \[ppb\] or parts per million \[ppm\]).

Steatosis as determined by in vitro hQSM, an MRI post-processing technique that provides quantitative information on iron levelsFive years

Quantitative susceptibility mapping (QSM) is widely used by the imaging research community in applications to detect iron. Tissue can become magnetized in response to a magnetic field, and the extent of magnetization is known as susceptibility, which arises from unpaired electrons in iron or external sources such as contrast agents. QSM permits visualization of the sizes and shapes of iron sources, delivers precise estimates of iron concentrations (units: parts per billion \[ppb\] or parts per million \[ppm\]).

Fibrosis as determined by in vivo hQSM, an MRI post-processing technique that provides quantitative information on iron levelsFive years

Quantitative susceptibility mapping (QSM) is widely used by the imaging research community in applications to detect iron. Tissue can become magnetized in response to a magnetic field, and the extent of magnetization is known as susceptibility, which arises from unpaired electrons in iron or external sources such as contrast agents. QSM permits visualization of the sizes and shapes of iron sources, delivers precise estimates of iron concentrations (units: parts per billion \[ppb\] or parts per million \[ppm\]).

Steatosis as determined by in vivo R2*, an MRI method that provides quantitative information on iron levelsFive years

R2\* is an imaging method used in MRI. R2\* = (1/T2\*) where R2\* is a relaxation rate measured in units of Hz (\[1/sec\]). R2\* is commonly used to look at iron levels by measuring the relaxation times of hydrogen nuclei affected by iron. The presence of the iron results in the shortening of proton relaxation times (T2\*), thus increasing R2\*.

Steatosis as determined by in vitro R2*, an MRI method that provides quantitative information on iron levelsFive years

R2\* is an imaging method used in MRI. R2\* = (1/T2\*) where R2\* is a relaxation rate measured in units of Hz (\[1/sec\]). R2\* is commonly used to look at iron levels by measuring the relaxation times of hydrogen nuclei affected by iron. The presence of the iron results in the shortening of proton relaxation times (T2\*), thus increasing R2\*.

Fibrosis as determined by in vivo R2*, an MRI method that provides quantitative information on iron levelsFive years

R2\* is an imaging method used in MRI. R2\* = (1/T2\*) where R2\* is a relaxation rate measured in units of Hz (\[1/sec\]). R2\* is commonly used to look at iron levels by measuring the relaxation times of hydrogen nuclei affected by iron. The presence of the iron results in the shortening of proton relaxation times (T2\*), thus increasing R2\*.

Fibrosis as determined by in vitro R2*, an MRI method that provides quantitative information on iron levelsFive years

R2\* is an imaging method used in MRI. R2\* = (1/T2\*) where R2\* is a relaxation rate measured in units of Hz (\[1/sec\]). R2\* is commonly used to look at iron levels by measuring the relaxation times of hydrogen nuclei affected by iron. The presence of the iron results in the shortening of proton relaxation times (T2\*), thus increasing R2\*.

Fibrosis as determined by in vitro hQSM, an MRI post processing technique that provides quantitative information on iron levelsFive years

Quantitative susceptibility mapping (QSM) is widely used by the imaging research community in applications to detect iron. Tissue can become magnetized in response to a magnetic field, and the extent of magnetization is known as susceptibility, which arises from unpaired electrons in iron or external sources such as contrast agents. QSM permits visualization of the sizes and shapes of iron sources, delivers precise estimates of iron concentrations (units: parts per billion \[ppb\] or parts per million \[ppm\]).

Necroinflammation as determined by in vivo hQSM, an MRI post-processing technique that provides quantitative information on iron levelsFive years

Quantitative susceptibility mapping (QSM) is widely used by the imaging research community in applications to detect iron. Tissue can become magnetized in response to a magnetic field, and the extent of magnetization is known as susceptibility, which arises from unpaired electrons in iron or external sources such as contrast agents. QSM permits visualization of the sizes and shapes of iron sources, delivers precise estimates of iron concentrations (units: parts per billion \[ppb\] or parts per million \[ppm\]).

Necroinflammation as determined by in vivo R2*, an MRI method that provides quantitative information on iron levelsFive years

R2\* is an imaging method used in MRI. R2\* = (1/T2\*) where R2\* is a relaxation rate measured in units of Hz (\[1/sec\]). R2\* is commonly used to look at iron levels by measuring the relaxation times of hydrogen nuclei affected by iron. The presence of the iron results in the shortening of proton relaxation times (T2\*), thus increasing R2\*.

Necroinflammation as determined by in vitro R2*, an MRI method that provides quantitative information on iron levelsFive years

R2\* is an imaging method used in MRI. R2\* = (1/T2\*) where R2\* is a relaxation rate measured in units of Hz (\[1/sec\]). R2\* is commonly used to look at iron levels by measuring the relaxation times of hydrogen nuclei affected by iron. The presence of the iron results in the shortening of proton relaxation times (T2\*), thus increasing R2\*.

Necroinflammation as determined by in vitro hQSM, an MRI post-processing technique that provides quantitative information on iron levelsFive years

Quantitative susceptibility mapping (QSM) is widely used by the imaging research community in applications to detect iron. Tissue can become magnetized in response to a magnetic field, and the extent of magnetization is known as susceptibility, which arises from unpaired electrons in iron or external sources such as contrast agents. QSM permits visualization of the sizes and shapes of iron sources, delivers precise estimates of iron concentrations (units: parts per billion \[ppb\] or parts per million \[ppm\]).

Trial Locations

Locations (2)

Weill Cornell Medical College

🇺🇸

New York, New York, United States

Columbia University Medical Center

🇺🇸

New York, New York, United States

© Copyright 2025. All Rights Reserved by MedPath