Can Changes in the Pleth Variability Index be Used to Predict Significant Hypotension During Spinal Anaesthesia for Caesarean Section?
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 17
- 试验地点
- 1
- 主要终点
- The primary outcome is the Pleth Variability Index change prior to a 20% fall in systolic blood pressure during spinal anaesthesia for a caesarean section.
研究概览
简要总结
During a caesarean section the blood pressure is usually measured every few minutes and it may fall too quickly to be detected in a timely fashion by this intermittent means. The monitor the Masimo Rainbow SET® (MRS) uses a peg attached to a finger to detect (amongst other things) the flow of blood through it. One of the measures it takes is called the Pleth Variability Index (PVI) which (unlike standard blood pressure measurement) it measures continuously. The investigators would like to try the MRS on patients to see if the PVI can be used to predict falls in blood pressure.
详细描述
BACKGROUND: When a baby is delivered by a surgical procedure (a Caesarean Section) the women will usually have a spinal anaesthetic. With a spinal anaesthetic local anaesthetic is injected into the spinal fluid to make the woman numb from her chest to her feet and this allows her to be comfortable but awake during the birth. One of the common side effects of a spinal anaesthetic is that the woman's blood pressure may fall making her feel unwell and (rarely) causing stress to the unborn baby. During a caesarean section the blood pressure is usually measured every few minutes and it may fall too quickly to be detected in a timely fashion by this intermittent means. The monitor the Masimo Rainbow SET® (MRS) uses a peg attached to a finger to detect (amongst other things) the flow of blood through it. One of the measures it takes is called the Pleth Variability Index (PVI) which (unlike standard blood pressure measurement) it measures continuously. The investigators have used the MRS on one of their patients who was having a caesarean section under a spinal anaesthetic and the PVI was seen to change before the patients blood pressure fell. Because this was only one case they would like to try the MRS on some more patients to see if the PVI can be used to predict falls in blood pressure. To keep a close eye on the blood pressure they would use another monitor called a finometer. A finometer measures blood pressure continuously by means of a small cuff that is placed around a finger. The finometer should allow them to follow changes in blood pressure more closely and see how these affect the PVI reading.
AIMS: The aim of this study is to see whether changes in PVI happen before a fall in blood pressure when a woman is having a spinal anaesthetic for a caesarean section.
METHODOLOGY: The women will have exactly the same anaesthetic as they would have had if they were not in the study. The investigators will simply be using two pieces of equipment (the MRS and the Finometer) to see what happens when and if the blood pressure falls.
EXPECTED OUTCOMES: The investigators hope that they will find that the PVI changes before the blood pressure falls significantly.
IMPLICATIONS: If this study were to be promising then the investigators could go on to perform another study where they use the MRS to help them decide when to give drugs and intravenous fluids to stop the blood pressure from falling.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 55 Years(Adult)
- 性别
- Female
- 接受健康志愿者
- 否
入选标准
- •Patients with a singleton uncomplicated pregnancy presenting for elective caesarean section under spinal anaesthesia where surgery and anaesthesia are anticipated to be uncomplicated.
排除标准
- •Age under 18
- •Conditions which may impair the ability of the technology to read accurately such as:
- •Reduced peripheral perfusion e.g. Raynaud's phenomenon
- •Circulating pigments e.g. bilirubin
- •Nail varnish that cannot be removed
- •Diseases of pregnancy: e.g. pregnancy induced hypertension
- •Significant coexisting maternal disease - e.g. congenital heart disease
- •Inability to speak fluent English
结局指标
主要结局
The primary outcome is the Pleth Variability Index change prior to a 20% fall in systolic blood pressure during spinal anaesthesia for a caesarean section.
时间窗: intraoperative
次要结局
未报告次要终点