MedPath

Effects of electrical stimulation of the calf muscle using a new textile electrode setup on blood flow and discomfort

Phase 1
Completed
Conditions
Deep vein thrombosis
Circulatory System
Phlebitis and thrombophlebitis of other deep vessels of lower extremities
Registration Number
ISRCTN49260430
Lead Sponsor
Karolinska University Hospital
Brief Summary

2022 Preprint results in https://doi.org/10.21203/rs.3.rs-1199890/v1 (added 20/12/2022) 2023 Results article in https://pubmed.ncbi.nlm.nih.gov/37145130/ (added 09/05/2023)

Detailed Description

Not available

Recruitment & Eligibility

Status
Completed
Sex
All
Target Recruitment
10
Inclusion Criteria

Healthy volunteers aged 18-75 years

Exclusion Criteria

1. Pregnancy
2. Skin ulcers
3. Previous surgery on blood vessels of the lower limbs
4. Pacemaker
5. Intracardiac defibrillator
6. Advanced heart disease
7. Kidney failure
8. Neuromuscular or metabolic disease

Study & Design

Study Type
Interventional
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Peak venous velocity in vena poplitea measured using Doppler ultrasound (CX50, Philips Medical Systems, Andover, MA, USA) during baseline and on three occasions during a 5-minute neuromuscular electrical stimulation of the calf
Secondary Outcome Measures
NameTimeMethod
Peak venous velocity in vena femoralis measured using Doppler ultrasound (CX50, Philips Medical Systems, Andover, MA, USA) during baseline and on three occasions during a 5-minute neuromuscular electrical stimulation of the calf