MedPath

Microsurgical Robot-assisted Corneal Transplant

Not Applicable
Not yet recruiting
Conditions
Corneal Dystrophy
Registration Number
NCT06844123
Lead Sponsor
CHU de Reims
Brief Summary

Full-thickness corneal grafting (transfixing keratoplasty) is a tissue graft described at the beginning of the 20th century, which has remained technically unchanged for several decades. Around 900 transfixing keratoplasties are performed every year in France. This microsurgical procedure is intended for patients with severe corneal pathology that seriously impairs visual function, and for whom no therapeutic alternative - optical devices, medication or other surgical procedure - exists.

The initial anatomical outcome of surgery depends on the accurate execution of the corneal sutures. Very recently, a robot with microsurgical capabilities was developed by the MMI company (Symani® surgical system, now available from the Reims University Hospital). This robot is equipped with forceps and a needle holder capable of handling fragile tissues and microsurgical needles with an amplitude of movement greater than that of the human hand. It is operated by a surgeon via a wireless controller and foot pedal. It could thus be used to perform the usual sutures of a transfixing keratoplasty.

To our knowledge, no study to date has evaluated the contribution of a microsurgical robot to transfixing keratoplasty in humans. The Symani® microsurgical robot recently received CE marking for microsurgery. The investigators were able to carry out a series of ex vivo keratoplasties using the robot to suture non-conforming human corneas (destined for destruction), thus proving the feasibility of the procedure.

On the basis of this proof of concept, our project aims to evaluate the performance of robot-assisted transfixing keratoplasty in patients requiring corneal transplantation. Robotic assistance for human eye surgery, particularly corneal transplants, has never been evaluated. The use of a robot to perform corneal sutures during transfixing keratoplasty could equal or even surpass the performance of this crucial surgical step, which is conventionally performed manually. Ultimately, visual results could be equivalent or even better than those obtained after conventional surgery. At the same time, the use of the robot will be evaluated in terms of surgical cost, in order to obtain a quantified financial evaluation of robot-assisted keratoplasty.

Detailed Description

Context Transfixing keratoplasty was developed in the early 20th century. The aim is to replace the entire central cornea with a corneal allograft. This microsurgical procedure is performed with the aid of an operating microscope, and under general anesthetic to ensure optimal control of the absence of movement and arteriovenous pressure throughout the procedure.

Suturing is therefore an essential part of transfixing keratoplasty. They determine the congruence of the tissue edges and the distribution of tension applied to the sutures, thus modulating the curvature (astigmatism) of the graft. This curvature will determine the optical properties of the eye, and hence its acuity and the patient's visual recovery. A topical immunomodulatory local treatment (corticosteroids and/or ciclosporin eye drops) is administered for several years; no systemic treatment is used. Sutures are usually removed 6 months to 1 year after surgery. Current indications are major declines in visual acuity - generally below 4/10 with the best possible correction - associated with i) severe keratoconus, the most frequent indication, ii) failed anterior grafts, iii) full-thickness central corneal scars, and iv) hereditary stromal dystrophies.

Robot-assisted surgery has developed considerably over the last twenty years, with procedures now routinely performed in macro- and endoscopic surgery (mainly urology, obstetrics and visceral surgery). Very recently, engineering advances in precision motion control and mechanical miniaturization have enabled the development of robots dedicated to microsurgery. The Symani® Surgical System (Medical MicroInstrument, Pisa, Italy) has been used and evaluated in animals and humans over the past two years for vessel and nerve microsurgery. The Symani® robot is equipped with forceps and a needle holder capable of handling fragile tissue, as well as microsurgical needles and wires (8/0 to 12/0). The Symani® robot has recently been CE-marked for microsurgery \[appendix 1\]. To date, there is only one study - ex vivo and in animals - on the feasibility of its use in ocular surgery. On the basis of the robot's capabilities and its CE mark, the investigators have carried out preliminary experiments, enabling us to envisage robot-assisted keratoplasty in humans.

On the basis of our preliminary results, the investigators hypothesize that it is possible to use the Symani® robot's assistance to perform the major surgical stage of transfixing keratoplasty, i.e. the sutures between the graft and the recipient cornea, in humans.

Objectives :

* Main:

1. Evaluate the feasibility, and intraoperative intercurrent events of robotic assistance during transfixing keratoplasty,

2. Identify possible early and late postoperative intercurrent events/adverse events related to robot use.

* Secondary :

i) Evaluate the impact of robotic assistance during transfixing keratoplasty on postoperative corneal anatomical outcome (graft curvature).

ii) Assess the impact of robotic assistance on refraction and visual outcome in the medium term: 3 months iii) Evaluate the mean degree of astigmatism post robotic-assisted grafting, so as to be able to calculate the number of subjects required for a subsequent study of the superiority of robotic-assisted surgery over usual conventional surgery.

iiii) Evaluate the additional cost of robotic-assisted surgery. iv) Evaluate the quality of life before and 3 months after the intervention Type of study: pilot feasibility study, monocentric, interventional. Population: Ten consecutive adult patients requiring transfixing keratoplasty who agreed to participate by signing an informed consent form.

Investigation plan : The study will be offered to patients scheduled for penetrating keratoplasty. Clinical follow-up will be conducted at Day 1, Day 7, Day 30. Final clinical and paraclinical check-up at Day 90 and end of participation.

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
10
Inclusion Criteria

Not provided

Exclusion Criteria

Not provided

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Primary Outcome Measures
NameTimeMethod
Descriptive analysis of unusual events intra- and postoperativelyDay O (intraoperative) to Day 7

Number and percentage of unusual events

Descriptive analysis of unusual eventsDay 7 to Day 90

Number and percentage of unusual events

Secondary Outcome Measures
NameTimeMethod
Postoperative corneal anatomical resultDay 90

Anterior topographic will be performed and compare central astigmatism

Visual acuity with correctionDay 90

The mean diopters

Subjective refractionDay 90

Measurement of refractive astigmatism (CYL)

Visual acuity without correctionDay 90

The mean diopters

Corneal topographic regularityDay 90

Corneal topographic regularity measured by surface asymmetry index (SAI)

Analysis of surgical costsMonth 6

cost of graft and materials used

National Eye Institute Visual Function QuestionnaireDay 90

Quality of life - National Eye Institute Visual Function Questionnaire

Trial Locations

Locations (1)

Chu Reims

🇫🇷

Reims, France

© Copyright 2025. All Rights Reserved by MedPath