Intubation During Resuscitation
- Conditions
- IntubationCardiopulmonary Resuscitation
- Interventions
- Device: The Bonfils Intubation FibrescopeDevice: The Video Rigid Flexing LaryngoscopeDevice: The C-MAC® S Video LaryngoscopeDevice: The Macintosh Laryngoscope
- Registration Number
- NCT02277951
- Lead Sponsor
- International Institute of Rescue Research and Education
- Brief Summary
The aim of the study was to compare time and success rates of four intubation devices ( in a cardiopulmonary scenario with uninterrupted chest compressions with a standardized manikin model.
The investigators hypothesized that fiberoscope laryngoscopes may improve success rates.
- Detailed Description
Devices using in study:
The Bonfils Intubation Fibrescope (BONFILS)(KARL STORZ Endovision, Inc., Charlton, MA, USA), The Video Rigid Flexing Laryngoscope (RIFL)( AI Medical Devices, Inc., Williamston, MI, USA), The C-MAC® S Video Laryngoscope Blade Mac#3(C-MAC®S) (KARL STORZ Endovision, Inc., Charlton, MA, USA) The Macintosh Laryngoscope Blade no. 3 (MAC) (LifeLine Medical, Inc., Brooksville, FL, USA).
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 141
- experienced emergency personnel: nurses, paramedics
- no experience in out-of-hospital emergency medicine
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Participants The Video Rigid Flexing Laryngoscope The Bonfils Intubation Fibrescope the Video Rigid Flexing Laryngoscope the C-MAC® S Video Laryngoscope the Macintosh Laryngoscope Participants The C-MAC® S Video Laryngoscope The Bonfils Intubation Fibrescope the Video Rigid Flexing Laryngoscope the C-MAC® S Video Laryngoscope the Macintosh Laryngoscope Participants The Bonfils Intubation Fibrescope The Bonfils Intubation Fibrescope the Video Rigid Flexing Laryngoscope the C-MAC® S Video Laryngoscope the Macintosh Laryngoscope Participants The Macintosh Laryngoscope The Bonfils Intubation Fibrescope the Video Rigid Flexing Laryngoscope the C-MAC® S Video Laryngoscope the Macintosh Laryngoscope
- Primary Outcome Measures
Name Time Method Success rate of ETI Subjects complete study in 1 day The devices to be compared include (1) The Bonfils Intubation Fibrescope , (2) the Video Rigid Flexing Laryngoscope, (3) the C-MAC® S Video Laryngoscope, (4) the Macintosh Laryngoscope. Successful intubation will be measured in the seconds from insertion of an intubation device to the first manual ventilation of the mannequin's lungs.
Time to successful intubation Subjects complete study in 1 day The devices to be compared include (1) The Bonfils Intubation Fibrescope , (2) the Video Rigid Flexing Laryngoscope, (3) the C-MAC® S Video Laryngoscope, (4) the Macintosh Laryngoscope. Successful intubation will be measured in the seconds from insertion of an intubation device to the first manual ventilation of the mannequin's lungs.
- Secondary Outcome Measures
Name Time Method