临床试验/NCT01328405
NCT01328405已完成4 期

The Air-Q Intubating Laryngeal Airway Versus the LMA-Proseal: A Prospective, Randomized Trial of Airway Seal Pressure

University of Wisconsin, Madison2 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2009年10月最近更新:
适应症

试验速览

阶段
4 期
状态
已完成
入组人数
100
试验地点
2
主要终点
Airway Seal Pressure

研究概览

简要总结

Introduction:

The air-QⓇ Intubating Laryngeal Airway (ILA) is a newer supraglottic airway. It is approved for use as a primary airway and as an aid for intubation in situations of anticipated or unanticipated difficult airways. A unique feature of this device as compared to other airways on the market is the size of the inner diameter (ID) and length of its airway tube. Direct placement of tracheal tubes > 7.5 mm ID through the airway tube is possible.

The ProSealTM LMA is considered the gold standard for supraglottic devices with respect to airway seal pressure. On average, it is reported to be approximately 28 cmH2O. This is significantly higher than that of the first generation LMA, the LMA-ClassicTM, which has a maximum seal pressure of 20 cmH2O, but averages 16-18 cmH2O in actual practice.

In this study the investigators aim to test whether the air-QⓇ creates an airway seal pressure that is similar to the LMA-ProSealTM, whether the position of the air-QⓇ in relation to the vocal cords, as assessed by fiberoptic endoscopy, is similar to that of the LMA-ProSealTM and whether airway morbidity is similar between the air-QⓇ and the LMA-ProSealTM.

详细描述

Introduction:

The air-QⓇ Intubating Laryngeal Airway (ILA) (Mercury Medical, Clearwater, Fl.) is a newer supraglottic airway. It is approved for use as a primary airway and as an aid for intubation in situations of anticipated or unanticipated difficult airways. A unique feature of this device as compared to other airways on the market is the size of the inner diameter (ID) and length of its airway tube. Direct placement of tracheal tubes > 7.5 mm ID through the airway tube is possible.

The ProSealTM LMA (LMA North America, La Jolla, CA) is considered the gold standard for supraglottic devices with respect to airway seal pressure. On average, it is reported to be approximately 28 cmH2O. This is significantly higher than that of the first generation LMA, the LMA-ClassicTM, which has a maximum seal pressure of 20 cmH2O, but averages 16-18 cmH2O in actual practice.

Pilot data from 50 insertions of the air-QⓇ at our institution places the device intermediate to the two aforementioned LMAs with regard to seal pressure, with a mean seal pressure of 23 (12-30) cmH2O.

Specific Aims:

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients who are 18 years or greater may be included if they presenting for any elective surgery or procedure to take place in any anesthetic location and require placement of a LMA for their surgery or procedure.

排除标准

  • non-English speaking
  • are a minor
  • are a prisoner
  • have impaired decision-making capacity or any condition for which the primary anesthesia team deems intubation with a tracheal tube to be necessary

结局指标

主要结局

Airway Seal Pressure

时间窗: Intraoperative (day 1)

The airway seal pressure will then be assessed by closing the APL valve on the anesthesia machine with a fresh gas flow of 5 liters/minute until an audible leak is observed.

次要结局

  • Glottic View(Intraoperative (day 1))
  • Grossly Visible Blood or Bile on LMA(Upon LMA removal)
  • Airway Pathology(Postoperative Day Two)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验