Factors affecting immediate extubation in the operating room after robotic lower abdominal oncological surgeries.
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- 入组人数
- 50
- 试验地点
- 1
- 主要终点
- 1.To assess the optic nerve sheath diameter as a determinant for extubation in robotic lower abdominal oncological surgeries
研究概览
简要总结
This study is a Prospective observational study for factors affecting immediate extubation in the operating room after lower abdominal oncological surgeries.Optic nerve sheath diameter is assessed with ultrasound guidance using a high frequency linear probe. ONSD is is a reliable method as a surrogate parameter of intracranial pressure during the perioperative period.The first measurement is taken 5 minutes after intubation in neutral position. Subsequent measurements will be taken at 30 minutes after placing in Trendelenburg position and after achieving pneumoperitoneum and just before the termination of pneumoperitoneum. The last measurement is taken 10 minutes after termination of pneumoperitoneum.
Parameters like the degree of Trendelenburg position will be noted using protractor, peak airway pressure will be noted half hourly starting from baseline, immediately after intubation, total IV fluids used will be noted. Duration of Trendelenburg position and duration of pneumoperitoneum will be noted.Intra abdominal pressure will be noted.
At the end of the surgery the pneumoperitoneum will be terminated and the patients are moved from the Trendelenburg position to neutral position. Immediate extubation is attempted if the standard criteria for extubation are met. If extubation could not be done within 20 mins, patient will be shifted to ICU for further management.
研究设计
- 研究类型
- Observational
入排标准
- 年龄范围
- 18.00 Year(s) 至 60.00 Year(s)(—)
- 性别
- All
入选标准
- •1.Patients undergoing robotic lower abdominal oncological surgery 2.Patients willing to give informed consent 3.Indivisuals of age between 18 to 60 years 4.ASA grade I and II patients.
排除标准
- •1.Patient refusal 2.Patients with raised intracranial pressure and intraocular pressure 3.Patients with restrictive and obstructive lung disease 4.Patients with h/o IHD.
结局指标
主要结局
1.To assess the optic nerve sheath diameter as a determinant for extubation in robotic lower abdominal oncological surgeries
时间窗: 3-4 hours
次要结局
- To assess the degree of Trendelenburg, duration of Trendelenburg, duration of surgery,peak airway pressure as determinants for extubation in robotic lower abdominal oncological surgeries(3-4 hours)
研究者
Dr Sinchana H P
Kidwai memorial institute of oncology