Evaluation of X-ray, Acetabular Guides and CT in THR

Not Applicable
Completed
Conditions
Total Hip Replacement
Interventions
Other: 2D X-ray templating technology
Device: Corin OPS™
Registration Number
NCT03072706
Lead Sponsor
University Hospitals Coventry and Warwickshire NHS Trust
Brief Summary

Total hip replacement is one of the most successful surgical procedures of modern times, with over 80,000 performed each year in the UK. However, up to 5% of all primary hip replacements need to be revised within the first 10 years, and in many cases malposition of the acetabular (hip socket) component is implicated in the early failure.

The standard method of positioning the acetabular component is for the surgeon to be guided by a combination of the visible anatomical landmarks within the surgical field, and the wider environment of the operating theatre. The advent of 3D printing has led to the development of custom-made surgical guides which can be used during surgery, in order to assist the surgeon in the positioning of instruments and devices. These surgical guides are manufactured based on CT or MRI imaging, and are designed to clearly indicate to the surgeon the desired location and orientation of bony cuts and implant positions.

This study will test the hypothesis that an acetabular alignment guide combined with three-dimensional CT-based planning using the Corin OPS™ (Optimised Positioning System), provides more accurate component alignment following primary total hip replacement compared with the current standard treatment, with the aim of improving patient outcomes and reducing the risk of complications of total hip replacement.

Detailed Description

Total hip replacement is one of the most successful surgical procedures of modern times, with over 80,000 performed each year in the UK. The vast majority of patients experience dramatic pain relief and improvement in function for many years. Despite this, however, there remains a significant risk of complications, including dislocation, leg length discrepancy, squeaking, and premature wear and failure of the implant. It is known that such complications are more likely to occur if the acetabular component is incorrectly positioned during the surgery. Up to 5% of all primary hip replacements need to be revised within the first 10 years, and in many cases malposition of the acetabular (hip socket) component is implicated in the early failure.

The Corin OPS™ offers such a custom-made acetabular alignment guide. Prior to the patient's surgery, a CT scan of the patient's pelvis \& legs is performed, and the images are used to produce a 3D computer model of the patient as they stand with a "virtual" hip replacement in place. Four additional X-rays of the pelvis and lumbar spine are also taken, with the patient adopting various predetermined "functional" positions (e.g. sitting in a chair, about to stand up). From these X-rays, the changes in the pelvic and femoral orientations can be measured for these functional positions. This data is then used to drive a simulation of the movement of the 3D computer model. The orientation of the components of the virtual hip replacement are then adjusted to optimise the biomechanical function of the joint. Once the proposed implant positions have been reviewed and approved by the surgeon, a custom-made acetabular orientation guide is 3-D printed and sterilised. During the surgery, this guide is fitted into the patient's acetabulum prior to implanting the components. Using a simple system of two sterile laser pointers, the orientation indicated by the guide can then be reproduced when the definitive acetabular component is implanted. There is no published data, however, on the accuracy of acetabular component positioning using this particular method. The standard of care in the UK for acetabular component positioning is the "freehand technique", where the surgeon is to be guided by a combination of the visible anatomical landmarks within the surgical field, and the wider environment of the operating theatre. It is important that the impact of this acetabular guide on acetabular component positioning be assessed in order to determine whether this intervention is likely to improve patient outcomes and reduce the risk of complications of total hip replacement.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
54
Inclusion Criteria
  • All patients undergoing an elective primary unilateral total hip replacement (THR) under the care of an orthopaedic consultant at University Hospitals Coventry and Warwickshire NHS Trust
  • Provision of written informed consent.
  • Male or Female aged 18-70 years.
  • Able and willing to comply with all study requirements.
Exclusion Criteria
  • Those patients deemed by the treating clinician as unsuitable for an uncemented primary acetabular implant for reasons such as

    1. Low demand patient
    2. Osteoporosis
    3. Significant acetabular bone loss
  • Patients with significant orthopaedic deformities (eg fused knee, hip or ankle).

  • Unable to undergo planning imaging (unable to stand or sit for X-rays, or to lie in a CT scanner).

  • Patients currently receiving ionising radiation treatment or scans for other medical conditions.

  • Previous entry in this trial (contralateral THR).

  • Participation in a clinical trial of an investigational medicinal product in the last 90 days.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Standard group2D X-ray templating technology2D X-ray templating technology
Corin OPS™Corin OPS™Corin Optimised Positioning System (OPS) Dynamic Hip Analysis
Primary Outcome Measures
NameTimeMethod
Acetabular cup anteversion angle6 weeks (+/- 2 weeks) post-surgery

The difference between planned and achieved acetabular cup anteversion assessed by post-operative CT scan

Secondary Outcome Measures
NameTimeMethod
Hip Disability & Osteoarthritis Outcome Score (HOOS)6-weeks, 4- and 12-months post-surgery

Hip Disability \& Osteoarthritis Outcome Score (HOOS): a validated, patient-reported measure of hip function.

Oxford Hip Score6-weeks, 4- and 12-months post-surgery

Oxford Hip Score: a validated, patient-reported measure of hip function

EQ-5D6-weeks, 4- and 12-months post-surgery

EQ-5D: a standardised measure of health and economic outcome.