Accuracy assessment of deformity correction using computer guided newer generation external fixator in deformities of thigh and leg bones
- Conditions
- Other specified acquired deformities of musculoskeletal system,
- Registration Number
- CTRI/2020/05/025480
- Lead Sponsor
- Maulana Azad Medical College
- Brief Summary
This study has been designed as a prospective interventional study to evaluate the accuracy of bony alignment using computer assisted hexapod fixator in correction of long bone deformities of lower limb in patients of age group of 18-60 years. Study will be conducted in India for a duration of 1 year. Outcome of the study will be assessed by residual angulation at CORA, reference lines and angles, residual LLD, time period of deformity correction, number of correction manoeuvres required.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- Not Yet Recruiting
- Sex
- All
- Target Recruitment
- 10
1.Clinico-radiologically diagnosed cases of lower limb deformities requiring treatment by Ilizarov method 2.Ilizarov fixator treated lower limb deformity cases with residual deformity after intra-operative acute correction manoeuvre.
1.Ilizarov fixator treated lower limb deformity cases where acceptable bony alignment could be achieved intra-operatively 2.Injuries on ipsilateral limb requiring vascular repair.
Study & Design
- Study Type
- Interventional
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method Accuracy of deformity correction will be assessed by following : Primary outcomes will be assessed at two timepoints – | 1.Immediately after application of computer assisted hexapod external fixator in postoperative period | 2.After completion of software prescribed correction manoeuvre A.Residual Angulation at CORA Primary outcomes will be assessed at two timepoints – | 1.Immediately after application of computer assisted hexapod external fixator in postoperative period | 2.After completion of software prescribed correction manoeuvre Opposite side alignment values will be considered as normal reference values. In case opposite side is also involved, standard reference values will be considered as normal values for evaluation purpose. Primary outcomes will be assessed at two timepoints – | 1.Immediately after application of computer assisted hexapod external fixator in postoperative period | 2.After completion of software prescribed correction manoeuvre B.Reference line and angles Primary outcomes will be assessed at two timepoints – | 1.Immediately after application of computer assisted hexapod external fixator in postoperative period | 2.After completion of software prescribed correction manoeuvre C.Value of residual torsional component of deformity, determined clinically Primary outcomes will be assessed at two timepoints – | 1.Immediately after application of computer assisted hexapod external fixator in postoperative period | 2.After completion of software prescribed correction manoeuvre D.Residual Limb length discrepancy (LLD) Primary outcomes will be assessed at two timepoints – | 1.Immediately after application of computer assisted hexapod external fixator in postoperative period | 2.After completion of software prescribed correction manoeuvre
- Secondary Outcome Measures
Name Time Method A.Manner’s grading of deformity (for accuracy assessment)2 B.Time period of Deformity correction
Trial Locations
- Locations (1)
Lok Nayak Hospital
🇮🇳Central, DELHI, India
Lok Nayak Hospital🇮🇳Central, DELHI, IndiaAnubhav VichitraPrincipal investigator9654737879anu.thundercharge@gmail.com