Accuracy of OPS™ Femoral Neck Resection Study
- Conditions
- Primary Total Hip Arthroplasty
- Interventions
- Device: Primary Total Hip Replacement with Trinity cup and MetaFix stem via direct anterior surgical approachDevice: Primary Total Hip Replacement with Trinity cup and TriFit TS stem via posterolateral surgical approach.
- Registration Number
- NCT03956381
- Lead Sponsor
- Corin
- Brief Summary
The primary objective of this study is to determine the accuracy of the Optimized Positioning System (OPS™) planning and delivery tools using different types of surgical approaches.
- Detailed Description
Total Hip Replacement (THR) is the gold standard for treatment of severe arthritis of the hip as it relieves pain, restores function of the joint and improves quality of life for patients. The restoration of hip mechanics can be influenced by the selected femoral stem design and also by choices made by the surgeon during the surgical implantation. The combination of femoral neck resection level and angle are key factors, particularly in cementless hip arthroplasty, in determining post-operative leg length and femoral anteversion. Historically, an estimation of prosthesis sizing and positioning has been made via a process of manual or digital templating either pre or intraoperatively using images of the implants positioned over the standard AP and lateral view hip x-rays taken in advance of surgery with generic instruments used during the surgery to execute the femoral head resection at the planned level. This process has a number of limitations. The OPS™ system utilizes detailed pre-operative imaging including a CT scan to generate a plan for the femoral neck resection level and angulation based on the anatomy of the individual patient. Following validation of this plan by the operating clinician, a patient specific femoral guide instrument is generated to help facilitate the reliable delivery of the planned resection intraoperatively. The purpose of this study will be to evaluate the use of the patient-specific femoral instrument in the hands of two surgeons using different prosthesis combinations and surgical approaches. A total number of 40 participants will be enrolled. Participants in this study will return for a single post-operative visit at 6 weeks to have X-rays taken and to enable any post-operative study hip related complications to be recorded. Once this has been completed, participants will be routinely followed-up by their orthopaedic surgeon as required in accordance with standard clinical practice.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 55
- Patients who understand the conditions of the study and are willing to return to the clinical site at 6 weeks post-operatively.
- Patients of either gender who are between 21-85 years inclusive.
- Patients with a diagnosis of osteoarthritis, rheumatoid arthritis or osteonecrosis and are considered by the Investigator to be clinically and medically suitable to undergo a primary total hip replacement
- Patients who meet the indications and none of the contraindications listed in the Instructions for Use (IFU) supplied by the manufacturer for the femoral stem and acetabular cup to be implanted.
- Patients who meet the indications and none of the contraindications listed in the Instructions for Use (IFU) supplied by the manufacturer for OPS™ Femoral Plan and OPS™ Femoral Patient Specific Instruments.
- Patients who are unable to provide informed consent.
- Patients who are unable to comply with all the required study procedures.
- Patients whose insurance will not cover the cost of the pre-operative CT and functional x-ray imaging required for use of the OPS system.
- Patients who are currently involved in any personal injury litigation, medical-legal or worker's compensations claims.
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description THR with OPS system-MetaFix/Trinity combination Primary Total Hip Replacement with Trinity cup and MetaFix stem via direct anterior surgical approach Hip prosthesis combination: MetaFix stem/ Trinity cup implanted by Surgeon 2 via a direct anterior approach according to their standard of practice. THR with OPS system-TriFit TS/Trinity combination Primary Total Hip Replacement with Trinity cup and TriFit TS stem via posterolateral surgical approach. Hip prosthesis combination: TriFit TS stem/ Trinity cup implanted by Surgeon 1 via a posterolateral approach according to their standard of practice.
- Primary Outcome Measures
Name Time Method Accuracy of the final osteotomy level compared to the selected OPS™ plan preopertively. 6 weeks post-op (+/- 2 weeks) Accuracy of the final osteotomy level compared to the selected OPS™ plan (+ or - 3mm). Two standard of care post-operative x-rays taken at 6 weeks will be used to evaluate the positioning of the total hip prosthesis from the resultant level of resection of the femoral neck. This parameter will be measured in mm.
- Secondary Outcome Measures
Name Time Method Comparison of the femoral stem size implanted compared to the selected OPS™ Plan preoperatively (± 1 size) Immediate postoperative The femoral stem size used during the operation will be compared to the selected one by the OPS™ Plan. This parameter will be measured in units.
Comparison of the acetabular cup size implanted compared to the selected OPS™ Plan preoperatively. Immediate postoperative The acetabular cup size used during the operation will be compared to the selected one by the OPS™ Plan. This parameter will be measured in mm.
Comparison of the femoral head size implanted compared to the selected OPS™ Plan preoperatively. Immediate postoperative The femoral head size used during the operation will be compared to the selected one by the OPS™ Plan. This parameter will be measured in mm.
Measurement of any change in Leg length/ femoral head height compared to the preoperative OPS™ Plan (± 5mm). 6 weeks post-op (+/- 2 weeks) The postoperative Leg length / femoral head height will be measured in mm and compared to the preoperative value.
Comparison of the acetabular cup orientation to the selected OPS™ Plan. 6 weeks post-op (+/- 2 weeks) The planned versus achieved acetabular cup orientation will be measured using 2D/3D registration software, in degrees.
Trial Locations
- Locations (1)
Colorado Joint Replacement
🇺🇸Denver, Colorado, United States