临床试验/NCT00641576
NCT00641576已完成不适用

A Study to Evaluate the Morse Taper Lock and Connection of the ACE Implant Internal-Connection and Its Effect of the Biological Gap

University of Alabama at Birmingham1 个研究点 分布在 1 个国家目标入组 23 人开始时间: 2005年4月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
23
试验地点
1
主要终点
Junctional stability between device and abutment

研究概览

简要总结

Dental implants are small metal posts that look like miniature screws. They are surgically implanted into the jawbone where they serve as substitute tooth roots. Implants are used in dentistry to reestablish function and aesthetics to areas of the mouth were natural teeth are missing.

Classical dental implants are made in two pieces. One part anchors in the jawbone and one part serves as a connecting post (an abutment) that attaches to a crown restoration or to attachment clasps that hold a denture in place.

Occasionally the materials used to fasten the two implant components together work their way loose and over time the abutment may begin to disconnect. If this happens a small gap appears between the implant and abutment. There are many reasons why this loosening occurs. One reason may be the design of the implant itself and another may be the way the two components are fastened together.

This study will assess the performance of an implant with a new design. The investigators hypothesize that using this implant design will reduce the risk of an implant-abutment disconnect and improve long-term success of implant therapy.

详细描述

While the external hex dental implant design has had very good clinical success, it is limited by retention screw loosening at the junction of the implant fixture and abutment; a situation that leads to micro-movement between components.

A number of clinical complications may arise when implant components separate. Micro-movement between the implant abutment and seating platform is thought to contribute to the formation of a "biological gap", the most notable consequence being gradual resorption of crestal alveolar bone over time.

We hypothesize that the "ACE CONNECT" two-piece implant design with an internal connection will limit screw loosening by providing a stable junction between the body of the implant and the abutment; a more stable junction will limit micro-movement and prevent the formation of a gap between components. Limiting the gap will lead to less inflammation of peri-implant soft tissues and reduced resorption of bone adjacent to the implant.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
19 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Need for replacement of non-adjacent missing teeth with dental implants
  • Edentulous in the area for more than 2 months
  • Minimum native bone height and width to receive a 10mm X 4mm implant

排除标准

  • Untreated decay or periodontal disease in residual dentition
  • Need for bone or soft-tissue augmentation in the proposed implant site
  • Pregnancy
  • Consistent use of medications likely to compromise bone healing
  • Chronic disease condition likely to compromise bone healing
  • Consistent smoking over 10 cigarettes during the immediate past 6 months

结局指标

主要结局

Junctional stability between device and abutment

时间窗: 24 months

次要结局

  • Peri-implant osseous support of the device(24 months)
  • Peri-implant soft-tissue response to the device(24 months)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Michael Reddy, DMD

Interin Dean

University of Alabama at Birmingham

研究点 (1)

Loading locations...

相似试验

Evaluation of the ACE Dental Implant | 临床试验