A Study to Evaluate the Morse Taper Lock and Connection of the ACE Implant Internal-Connection and Its Effect of the Biological Gap
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 23
- 试验地点
- 1
- 主要终点
- Junctional stability between device and abutment
研究概览
简要总结
Dental implants are small metal posts that look like miniature screws. They are surgically implanted into the jawbone where they serve as substitute tooth roots. Implants are used in dentistry to reestablish function and aesthetics to areas of the mouth were natural teeth are missing.
Classical dental implants are made in two pieces. One part anchors in the jawbone and one part serves as a connecting post (an abutment) that attaches to a crown restoration or to attachment clasps that hold a denture in place.
Occasionally the materials used to fasten the two implant components together work their way loose and over time the abutment may begin to disconnect. If this happens a small gap appears between the implant and abutment. There are many reasons why this loosening occurs. One reason may be the design of the implant itself and another may be the way the two components are fastened together.
This study will assess the performance of an implant with a new design. The investigators hypothesize that using this implant design will reduce the risk of an implant-abutment disconnect and improve long-term success of implant therapy.
详细描述
While the external hex dental implant design has had very good clinical success, it is limited by retention screw loosening at the junction of the implant fixture and abutment; a situation that leads to micro-movement between components.
A number of clinical complications may arise when implant components separate. Micro-movement between the implant abutment and seating platform is thought to contribute to the formation of a "biological gap", the most notable consequence being gradual resorption of crestal alveolar bone over time.
We hypothesize that the "ACE CONNECT" two-piece implant design with an internal connection will limit screw loosening by providing a stable junction between the body of the implant and the abutment; a more stable junction will limit micro-movement and prevent the formation of a gap between components. Limiting the gap will lead to less inflammation of peri-implant soft tissues and reduced resorption of bone adjacent to the implant.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 19 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Need for replacement of non-adjacent missing teeth with dental implants
- •Edentulous in the area for more than 2 months
- •Minimum native bone height and width to receive a 10mm X 4mm implant
排除标准
- •Untreated decay or periodontal disease in residual dentition
- •Need for bone or soft-tissue augmentation in the proposed implant site
- •Pregnancy
- •Consistent use of medications likely to compromise bone healing
- •Chronic disease condition likely to compromise bone healing
- •Consistent smoking over 10 cigarettes during the immediate past 6 months
结局指标
主要结局
Junctional stability between device and abutment
时间窗: 24 months
次要结局
- Peri-implant osseous support of the device(24 months)
- Peri-implant soft-tissue response to the device(24 months)
研究者
Michael Reddy, DMD
Interin Dean
University of Alabama at Birmingham
