Model-based Iterative Reconstruction (MB-IR VEOTM) in Ultra Low-dose Abdominal CT Versus Adaptative Statistical Iterative Reconstruction (ASIR): A Prospective Study for Acute Renal Colic

Not Applicable
Completed
Conditions
Model-based Iterative Reconstruction (MB-IR VEOTM)
Interventions
Device: Model-based iterative reconstruction (MB-IR VEOTM) on CT Discovery 750HD (GE Healthcare, Milwaukee, WI)
Registration Number
NCT02076737
Lead Sponsor
University Hospital, Clermont-Ferrand
Brief Summary

The purpose of this study is to determine if Model-based iterative reconstruction (MB-IR VEOTM) in ultra low-dose abdominal CT as the same accuracy for the diagnosis of acute renal colic versus standard CT with adaptative statistical iterative reconstruction (ASIR).

Detailed Description

Renal colic is a common recurrent pathology in young patients, multi explored by imaging such as CT and abdominal radiography.

Abdominal MDCT(MultiDetector Computed Tomography) without injection is the gold standard in diagnosis of acute flank pain suspect of renal colic due to high sensitivity (96%) and excellent specificity (100%).

The increased use of medical imaging examinations using ionizing radiation (+57 % between 2002 and 2007) makes it essential to optimize protocols, including CT-scans which represents 10.1 % of procedures and 58 % of the collective effective dose.

Model-based iterative reconstruction (MB-IR VEOTM) (GE Healthcare, Milwaukee, WI) can use a low dose acquisition, reducing the effective dose delivered to the patient almost 80% comparing a standard CT with the last algorithm: adaptative statistical iterative reconstruction (ASIR).

MB-IR VEOTM shows great potential for substantially reducing radiation doses at routine abdominal CT. ASIR is limited in this regard owing to reduced image quality and diagnostic capability. Further investigation is needed to determine the optimal dose level for MBIR(Model Base Iterative Reconstruction) that maintains adequate diagnostic performance. In general, objective and subjective image quality measurements do not necessarily correlate with diagnostic performance at ultralow-dose CT.

Objective:

Prospective clinical study, equivalence between two CT protocols for the diagnosis of acute renal colic.

Show that a low dose acquisition with model based iterative reconstruction (MB-IR VeoTM) is as good as a standard CT with adaptative statistical iterative reconstruction (ASIR) in the diagnosis acute renal colic

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
120
Inclusion Criteria
  • Informed and a written consent
  • Acute flank pain needed abdominal CT exploration.
Exclusion Criteria
  • Juvenile patients
  • Pregnant women

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
VEOModel-based iterative reconstruction (MB-IR VEOTM) on CT Discovery 750HD (GE Healthcare, Milwaukee, WI)-
Primary Outcome Measures
NameTimeMethod
acute renal colicat day 1
Secondary Outcome Measures
NameTimeMethod
Measure of dose-length productat day 1
Measurements of subjective image qualityat day 1
Evaluation of visceral fatat ady 1