Comparison of the Accuracy Between Technique V and Arterial Palpation Techniques in Determining the Location of the Femoral Veins
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 115
- 试验地点
- 2
- 主要终点
- prediction of femoral vein location
研究概览
简要总结
This study aimed to determine the accuracy of the V technique in predicting the location of the femoral vein compared to the technique of palpating the femoral artery with the use of USGss as a standard in determining the exact location of the femoral vein.
详细描述
One hundred and fifteen subjects were allocated into two large groups, V tecnique group and palpation tecnique group. Researchers will perform the V technique on the patient's inguinal area. This technique was performed using the researcher's contralateral hand. After the V technique is performed, the next researcher will perform the technique of palpating the femoral artery pulse at the exact location as the V technique. This technique is done by palpating the femoral artery pulsation using the examiner's index and middle fingers along the inguinal ligament; the location of the femoral vein is at 1 cm. medial to the femoral artery 2 cm inferior to the inguinal ligament. This location is marked "y" with a UV marker. researchers will compare the accuracy of both techniques in determining the exact location of femoral veins.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Supportive Care
- 盲法
- Single (Investigator)
入排标准
- 年龄范围
- 18 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •patients aged 18-65 years
- •body mass index (BMI) of 18-25 kg/m2
排除标准
- •could not lie supine
- •had congenital or acquired abnormalities in the pelvic and inguinal region
- •had a history of previous femoral vein puncture
- •allergic to USG gel
结局指标
主要结局
prediction of femoral vein location
时间窗: intra procedural
Researcher will identify femoral vein location
次要结局
未报告次要终点
研究者
Aida Rosita Tantri
Doctor
Indonesia University