MedPath

Validation of a 13C Glucose Breath Test Compared With the Euglycaemic Clamp Test

Conditions
Insulin Resistance
Type 1 Diabetes
Interventions
Diagnostic Test: euglycaemic clamp test
Diagnostic Test: 13C glucose breath test
Registration Number
NCT04623320
Lead Sponsor
University Hospital, Antwerp
Brief Summary

Insulin resistance can be assessed by the euglycaemic clamp technique. To date, this is the golden standard, but it is not suited for clinical practice. A 13C glucose breath test will be tested as a valid alternative. The curve of the exhaled 13C CO2 as a function of glucose metabolism can be correlated to the curve of the glucose disposal rate obtained via the clamp technique.

Detailed Description

The hyperinsulinemic-euglycemic clamp technique is the golden standard to assess insulin resistance in type 1 diabetes subjects. The plasma insulin concentration is acutely raised and maintained at 100 μU/ml by a continuous infusion of insulin. Meanwhile, the plasma glucose concentration is held constant at basal levels by a variable glucose infusion. When the steady-state is achieved, the glucose infusion rate equals glucose uptake by all the tissues in the body and is therefore a measure of tissue insulin sensitivity.

These data will be compared with the results of a 13C glucose breath test. Breath tests using 13C substrates are based on the principle that 13C CO2 in the exhaled breath can be measured as a metabolic tracer.

Breath testing has a major advantage over the clamp test in that it can be performed non-invasively and repeatedly without necessary supervision by medical staff.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
50
Inclusion Criteria
  • Adult type 1 diabetes patients
  • 25/50 subjects with confirmed NAFLD (using ultrasound criteria)
Exclusion Criteria
  • pregnancy
  • gastric bypass surgery
  • cirrhosis
  • secondary cause of liver steatosis present
  • any cause which makes a 4-hour clamp impossible

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
NAFLD-T1DM+13C glucose breath testSubjects with type 1 diabetes without ultrasound-defined NAFLD
NAFLD+T1DM+13C glucose breath testSubjects with type 1 diabetes and ultrasound-defined NAFLD
NAFLD-T1DM+euglycaemic clamp testSubjects with type 1 diabetes without ultrasound-defined NAFLD
NAFLD+T1DM+euglycaemic clamp testSubjects with type 1 diabetes and ultrasound-defined NAFLD
Primary Outcome Measures
NameTimeMethod
Correlation of the 13C breath test with the golden standardone day

sensitivity and specificity analysis using linear regression

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Antwerp University Hospital

🇧🇪

Antwerp, Belgium

© Copyright 2025. All Rights Reserved by MedPath