MedPath

Effects on Septic Patient's Microcirculation of the Transfusion of Different Types of Concentrated RBCs.

Phase 4
Completed
Conditions
Septic Patients
Interventions
Biological: Blood transfusion
Registration Number
NCT01584999
Lead Sponsor
Università Politecnica delle Marche
Brief Summary

Aim of the study is to evaluate the effects, on microcirculation of septic patient, of three types of RBCs: 1- fresh standard RBCs (storage \<10 days); 2-leukodepleted RBCs and 3-old standard RBCs (storage \>15 days) respectively. Before and 1 hour after the transfusion, microcirculation is evaluated using Sidestream Dark Field Imaging (SDF) and Near InfraRed Spectroscopy (NIRS) with vascular occlusion test. We also monitor temperature, heart rate, mean blood pressure, hemochrome, blood gases, blood lactates and SOFA score.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
30
Inclusion Criteria
  • Patients with sepsis, severe sepsis or septic shock who, according to clinical evaluation, need a hemotransfusion.
Exclusion Criteria
  • Patients under 18 years of age; Pregnancy; Coagulative disorders; Cardiogenic shock (Met<4;)Acute massive bleeding (>8 U)

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Fresh not-leukocyte-reduced RBCsBlood transfusion-
Fresh RBCs leukocyte-reducedBlood transfusion-
RBCs with storage longer than 15 daysBlood transfusion-
Primary Outcome Measures
NameTimeMethod
Microcirculatory Flow Index (MFI) before and after blood transfusion.One hour after the end of blood transfusion compared with before blood transfusion

Microcirculatory Flow Index detected in vivo by side-dark field imaging at sublingual microcirculation. It represents the quality of blood flow at microcirculatory level. This study wants to verify any of the considered different types of blood transfused can improve MFI.

Secondary Outcome Measures
NameTimeMethod
Perfused Vessel Density (PVD)One hour after the end of blood transfusion compared with before blood transfusion

Perfused Vessel Density detected in vivo by side-dark field imaging at sublingual microcirculation. It represents the quantity of well perfused vessels at microcirculatory level. This study wants to verify any of the considered different types of blood transfused can improve PVD.

StO2 upslopeOne hour after the end of blood transfusion compared with before blood transfusion

StO2 upslope is measured with Near InfraRed Spectroscopy at the tenar muscle. It represents the velocity of the recovery of the tissue oxygen saturation after a short period of ischemia of the hand, the Vascular Occlusion Test.

Arterial Blood LactateOne hour after the end of blood transfusion compared with before blood transfusion
Arterial pHOne hour after the end of blood transfusion compared with before blood transfusion
SOFA scoreOne hour after the end of blood transfusion compared with before blood transfusion

Trial Locations

Locations (1)

University ICU, AOU Ospedali Riuniti

🇮🇹

Torrette di Ancona, Ancona, Italy

© Copyright 2025. All Rights Reserved by MedPath