Infiltration Effect on SUV
- Conditions
- Dose Response Relationship, Drug
- Interventions
- Diagnostic Test: F-18 FDG PET
- Registration Number
- NCT03320564
- Lead Sponsor
- Wake Forest University Health Sciences
- Brief Summary
A widely used semi-quantitative parameter to assess tumor status is the standardized uptake value (SUV). SUV estimation accuracy can be impacted by many variables. Today there still exists a significant amount of variability in PET/CT results in test and re-test studies. This variability can be introduced by instrumentation and subject-specific factors. Variability reduces image quality and increases the required changes in tumor quantification to reflect real tumor response or progression.
PET/CT scanning process requires that the entire net injected dose of radiolabeled tracer is administered intravenously as a bolus. The quality and quantification of a PET/CT image is highly dependent on the uptake of radiolabeled tracer. Boellaard et al. have indicated infiltrations could potentially underestimate SUV measurements by as much as 50%. Infiltrations and obstructions are not uncommon.
Recent studies using a novel QA/QC tool (LaraTM System) for the radiotracer injection process revealed that current means to detect infiltration do not completely identify all infiltrations/obstructions. Since infiltrations may not be visible in the standard field of view (FOV) and since the impact of a peripheral circulatory obstruction may not be visible even if an injection site is in the FOV, it is possible for reading and treating physicians to be unaware that a patient's image and quantification has been impacted. Additionally, when current means do detect an infiltration, they under-represent the severity because they are not capturing that infiltrations often resolve during the uptake period. As a result, infiltrations or obstructions may cause SUV inaccuracy and could adversely impact staging and tumor assessments.
The purpose of this study will be to characterize the impact of moderate or greater infiltrations on standardized uptake values. Patients experiencing a moderate or greater infiltration on a routine clinical PET scan will be invited to return for a repeat scan with injection performed by specially trained personnel to reduce the risk of repeat infiltration. The two scans will be compared to assess for changes in tumor uptake intensity.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- TERMINATED
- Sex
- All
- Target Recruitment
- 2
- Subjects with solid tumors undergoing PET/CT scan who have at least one measurable target lesion and sustain a moderate or greater infiltration.
- Subjects unwilling or unable to tolerate a repeat PET/CT scan.
- Subjects with meaningful medical intervention between PET/CT scans that would likely impact SUV.
- Subjects with follow up injection infiltrations that would likely impact the SUV.
- Pregnant patients.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Infiltration F-18 FDG PET Repeat F-18 FDG PET
- Primary Outcome Measures
Name Time Method Change in SUVpeak of Target Lesions Between Infiltrated and Non-infiltrated Scans Baseline scan and follow up scan within 7 days Target lesions selected as per PERCIST criteria. These criteria require more space than allowed to explain. Reference J Nucl Med 2009; 50: 122S-150S. DOI: 10.2967/jnumed.108.057307
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Wake Forest Baptist Health
🇺🇸Winston-Salem, North Carolina, United States