Aortic-Radial Pressure Gradients Post CPB

Completed
Conditions
Coronary Artery Disease
Registration Number
NCT03142815
Lead Sponsor
University of Iowa
Brief Summary

This study will examine whether pre-operative, non-invasive arterial stiffness measurements can be used to predict which patients will develop an aortic-to-radial pressure gradient after coronary artery bypass graft (CABG) surgery. A previous small study by Kanazawa, et al. demonstrated in patients who developed an aortic-to-radial pressure gradient after CABG surgery, the pulse wave velocity (PWV) was higher in the aorta and decreased when moving toward the radial artery. In the patients who did not develop a pressure gradient, the PWV started lower in the aorta and increased when moving towards the periphery.

The purpose of this investigation is to examine whether pre-operative PWV measurements can be used to identify patients who will develop an aortic to radial pressure gradient after CABG surgery.

Applanation tonometry will be performed on the right carotid and femoral arteries to assess carotid-femoral pulse wave velocity, a surrogate for aortic stiffness. (SphygmoCor system, AtCor Medical, Sydney, Australia). The measurement will be obtained before induction of general anesthesia in the presurgical area. Also in the presurgical area, a non-invasive cardiac output (CO) measurement will be obtained by using the ICON Device (Osypka Medical, La Jolla, California). This CO value will be used to compare to the CO values obtained invasively in the operating room.

Detailed Description

The purpose of the study is determine if there is a relationship between pre-operative vascular characteristics including, carotid-femoral pulse wave velocity (cfPWV), Augmentation Index(AI) and central aortic pressure, and the development of a pressure gradient between the aorta and radial artery after cardiopulmonary bypass.

The procedures necessary to achieve the desired outcomes are as follows. The first measurement made by the research team will be pre-operative cardiac output (CO) measurement. The ICON device is a non-invasive device that measures CO, or the amount of blood that your heart pumps per minute. This device utilizes four stickers that are attached to skin, two on the left side of the neck and two located on the left side of the chest. These stickers function similarly to electrocardiogram (EKG) stickers that measure the electrical activity of your heart. After attachment of the stickers, the ICON device will be used to make a measurement of CO, which takes 1-2 minutes. After the measurement, the stickers will be removed and the ICON device will not be used again in the study.

Secondly, pre-operative cfPWV, AI, and central aortic pressure measurements will be made. The Sphygmocor device will be utilized to make the pre-operative cfPWV, AI and central aortic pressure measurements. First, the AI measurements will be made using a non-invasive blood pressure cuff placed on the right arm. The patient's blood pressure will be measured twice in a row with this special blood pressure cuff. The blood pressure cuff on the right arm will be removed and then a cuff will be placed around the right thigh. Measurements will be made with a paper ruler from the patient's neck to the cuff on their leg. To make the cfPWV measurements, the cuff on the thigh will inflate while a pressure probe will be placed on the skin of the patient's right neck. Four measurements of cfPWV will be made with this technique.

The intraoperative central aortic pressure measurement will be accomplished with the help of the cardiothoracic surgeon. The surgeon will place a catheter in the aorta as part of the coronary artery bypass grafting surgery. This catheter will be connected to the artificial heart-lung machine. Prior to turning on the heart-lung machine, the pressure in the aorta will be measured with this catheter. This is the standard of care for this type of surgery and will not delay the surgery. After the artificial heart-lung machine is turned off but before the catheter is removed from the aorta, the pressure will once again be measured.

In order to measure intraoperative CO values, we will utilize the pulmonary artery (PA) catheter that was placed at the beginning of the surgery.. The patient will have a catheter placed in the right side of the neck that will travel through the heart and into a branch of the artery that goes from the heart to the lungs. This catheter will have the ability to measure the amount of blood that is pumped from the heart per minute. At the same times that the pressure in the aorta is measured (as above), the amount of blood that is pumped from the heart per minute will be measured.

Lastly measurement of peripheral artery blood pressure will be accomplished with a right radial arterial catheter. Prior to the start of surgery, the patient will receive a special catheter in the radial artery of their right arm. This is the standard of care for blood pressure monitoring in this type of surgery. At the same times during the surgery that the pressure is being measured from the aortic catheter, the pressure will be measured from the catheter in the right radial artery.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
90
Inclusion Criteria
  • Adult patients, age 40-80, who are scheduled to undergo elective coronary artery bypass graft (CABG) surgery at the University of Iowa Hospitals and Clinics.
Exclusion Criteria
  • off-pump CABG surgery, emergency cases, patients who already have a balloon pump or major valvular heart disease, and if preoperative PWV is not obtainable for any reason.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Comparison of pre-operative carotid-femoral pulse wave velocity (cfPWV)between patients who develop an aortic-to-radial pressure gradient after coronary artery bypass surgery and those who don't develop a pressure gradient1 day (day of surgery)

The study is aimed to compare cfPWV between patients who develop an aortic-to-radial pressure gradient after coronary artery bypass and those who don't who are undergoing coronary artery bypass graft surgery. Arterial stiffness will be measured by pulse wave velocity (m/s) with a SphygmoCor® device (Atcor, Sydney, Australia)

Comparison of AI between patients who develop an aortic-to-radial pressure gradient and those who don't a pressure gradient1 day (day of surgery)

The study is aimed to compare AI between patients who develop an aortic-to-radial pressure gradient after coronary artery bypass and those who don't who are undergoing coronary artery bypass graft surgery. Arterial stiffness will be measured by pulse wave velocity (m/s) with a SphygmoCor® device

Secondary Outcome Measures
NameTimeMethod
CO1 day (day of surgery)

Cardiac Output before and after coronary artery bypass

SVR1 day (day of surgery)

Systemic vascular resistance before and after coronary artery bypass

Aortic pressure1 day (day of surgery)

Central aortic pressure will be measured before and after bypass.

Pulse pressure1 day (day of surgery)

Pulse pressure will be measured.

Risk factors1 day (day of surgery)

Pre-operative risk factors will be examined for any indication of development of aortic-to-radial pressure gradient after coronary artery bypass graft surgery.

Trial Locations

Locations (1)

University of Iowa Hosptials and Clinics

🇺🇸

Iowa City, Iowa, United States