跳至主要内容
临床试验/NCT04712513
NCT04712513Unknown不适用

Multicenter Diagnostic Performance of Dynamic CT Perfusion for Functional Assessment of Coronary Artery Disease

Lawson Health Research Institute1 个研究点 分布在 1 个国家目标入组 240 人开始时间: 2021年3月最近更新:
适应症

试验速览

阶段
不适用
入组人数
240
试验地点
1
主要终点
Accuracy of myocardial perfusion obtained from dynamic cardiac CT perfusion imaging for detecting functionally significant coronary artery stenosis

研究概览

简要总结

The objective of this multicenter study is to evaluate the diagnostic accuracy of dynamic cardiac CT perfusion (CTP) imaging for non-invasive functional assessment of coronary artery disease (CAD). The proposed CTP technique allows concomitant assessment of two imaging-derived cardiac biomarkers including fractional flow reserve (FFR) and myocardial perfusion from a single dynamic imaging sequence, which facilities simultaneous evaluation of the hemodynamics in epicardial coronary arteries and coronary microcirculation in patients with CAD. The CTP results will be compared with invasive coronary angiography / FFR assessment and non-invasive cardiac magnetic resonance imaging (CMR) / radionuclide perfusion assessment.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
30 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

Accuracy of myocardial perfusion obtained from dynamic cardiac CT perfusion imaging for detecting functionally significant coronary artery stenosis

时间窗: Within 4 weeks prior to invasive cardiac catheterization

Comparison with invasive coronary angiography and FFR assessment

Comparison of diagnostic accuracy for functional CAD assessment between dynamic CT perfusion and static CT perfusion

时间窗: Within 4 weeks prior to invasive cardiac catheterization

Comparison in patients with multi-vessel CAD where balanced ischemia is expected

Accuracy of combined myocardial perfusion and FFR measurement obtained from dynamic cardiac CT perfusion imaging for detecting functionally significant coronary artery stenosis

时间窗: Within 4 weeks prior to invasive cardiac catheterization

Comparison with invasive coronary angiography and FFR assessment

Comparison of diagnostic accuracy for functional CAD assessment between dynamic CT perfusion and CT-FFR (based on computational fluid dynamics simulation)

时间窗: Within 4 weeks prior to invasive cardiac catheterization

Comparison in patients with dense coronary calcification

Accuracy of FFR obtained from dynamic cardiac CT perfusion imaging for detecting functionally significant coronary artery stenosis

时间窗: Within 4 weeks prior to invasive cardiac catheterization

Comparison with invasive coronary angiography and FFR assessment

次要结局

  • Comparison of diagnostic accuracy for functional CAD assessment between dynamic CT perfusion and other non-CT perfusion imaging techniques(Within 4 weeks of the acquisition of non-CT perfusion imaging)
  • Comparison of diagnostic accuracy of dynamic CT perfusion for functional CAD assessment between male and female patients(Within 4 weeks prior to invasive cardiac catheterization)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Aaron So

Scientist

Lawson Health Research Institute

研究点 (1)

Loading locations...

相似试验