An Early Feasibility Evaluation of the AccuCinch® Ventricular Restoration System in Patients With Heart Failure and Reduced Ejection Fraction (HFrEF) - The CorCinch-HFrEF Study

Ancora Heart, Inc.18 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2018年8月23日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
进行中(未招募)
入组人数
22
试验地点
18
主要终点
Safety measured by device-related or procedure-related major adverse events (MAEs)

研究概览

简要总结

This is a non-randomized, prospective, multi-center Early Feasibility Study to evaluate the AccuCinch® Ventricular Restoration System in Patients with Heart Failure and Reduced Ejection Fraction (HFrEF).

详细描述

Device name changed from AccuCinch® Ventricular Repair System to AccuCinch® Ventricular Restoration System, FDA Approval Date 08Aug2020.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Study patient is at least 18-years old
  • •Ejection Fraction: ≥20 and ≤40%
  • •LV end-diastolic diameter ≥55 mm
  • •Symptom Status: NYHA III-IV (i.e., ambulatory)
  • •Treatment and compliance with optimal guideline directed medical and device-based therapies for heart failure (unless contraindicated or intolerant) for at least 3 months and stable doses for 1 month with stable defined as no more than 100% increase or 50% decrease of total daily doses.
  • •Patients with left bundle branch block pattern and QRS duration >150ms are required to have a CRT device for at least 3 months
  • •Patients required to have an ICD are required to have ICD implant at least 1 month prior to enrollment
  • •Able and willing to complete all qualifying diagnostic and functional tests and agrees to comply with study follow-up schedule

排除标准

  • •Myocardial infarction or any percutaneous cardiovascular intervention, cardiovascular surgery, or carotid surgery within 3 months
  • •Mitral regurgitation grade 3 (moderate-severe) or more
  • •Prior surgical, transcatheter, or percutaneous mitral valve intervention
  • •Untreated clinically significant coronary artery disease (CAD) requiring revascularization
  • •Hemodynamic instability: Hypotension (systolic pressure <90 mmHg) or requirement for inotropic support or mechanical hemodynamic support
  • •Any planned cardiac surgery or interventions within the next 6 months (including right heart procedures)
  • •NYHA class IV (i.e., non-ambulatory)
  • •Significant RV dysfunction (TAPSE < 14)
  • •Severe tricuspid regurgitation
  • •Hypertrophic cardiomyopathy, restrictive cardiomyopathy, constrictive pericarditis, or any other structural heart disease causing heart failure other than dilated cardiomyopathy of either ischemic or non-ischemic etiology
  • •Anatomical pathology or constraints preventing appropriate access/implant of the AccuCinch® Ventricular Repair System (e.g., femoral arteries will not support a 20F system)
  • •Renal insufficiency (i.e., eGFR of <30ml/min/1.73m2; Stage 4 or 5 CKD)
  • •Moderate or severe aortic valve stenosis or regurgitation or aortic valve prosthesis
  • •Fluoroscopic or echocardiographic evidence of severe aortic arch calcification, mobile aortic atheroma, intracardiac mass, thrombus or vegetation
  • •Active bacterial endocarditis
  • •History of any stroke within the prior 3 months or Modified Rankin Scale ≥ 4 disability from any prior stroke
  • •Subjects in whom anticoagulation or antiplatelet therapy is contraindicated
  • •Known allergy to nitinol, polyester, or polyethylene
  • •Any prior true anaphylactic reaction to contrast agents; defined as known anaphylactoid or other non-anaphylactic allergic reactions to contrast agents that cannot be adequately pre-medicated prior to the index procedure.
  • •Life expectancy < 1 year due to non-cardiac conditions
  • •Currently participating in another interventional investigational study
  • •Implant or revision of any rhythm management device (CRT or CRT-D) prior 3 months or implantable cardioverter defibrillator within the prior 1 month
  • •Subjects on high dose steroids or immunosuppressant therapy
  • •Female subjects who are pregnant, of child bearing potential without a documented birth control method, or lactating

研究组 & 干预措施

AccuCinch® Ventricular Restoration System

Experimental

干预措施: AccuCinch® Ventricular Restoration (Device)

结局指标

主要结局

Safety measured by device-related or procedure-related major adverse events (MAEs)

时间窗: 30-day

Device-related or procedure-related major adverse events (MAEs)

次要结局

未报告次要终点

研究者

申办方类型
Industry