跳至主要内容
临床试验/NCT02806570
NCT02806570已完成不适用

Early Feasibility Study of the AccuCinch® Ventricular Restoration System

Ancora Heart, Inc.16 个研究点 分布在 1 个国家目标入组 35 人开始时间: 2016年8月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
35
试验地点
16
主要终点
30-Day Safety

研究概览

简要总结

This is a multi-center, non-randomized, prospective Early Feasibility Study to evaluate the AccuCinch® Ventricular Restoration System in patients with symptomatic heart failure and concomitant functional mitral regurgitation that have stable symptoms on guideline-directed medical therapy

详细描述

Device name changed from AccuCinch® Ventricular Repair System to AccuCinch® Ventricular Restoration System, FDA Approval Date 08Aug2020

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Study patient is at least 18-years old
  • •Severity of FMR: ≥ Moderate (i.e., 2+, according to Stone et al Clinical Trial Design Principles and Endpoint Definitions for Transcatheter Mitral Valve Repair and Replacement: Part 1: Clinical Trial Design Principles. A Consensus Document from the Mitral Valve Academic Research Consortium11; and 2003 ASE Guidelines for grading mitral regurgitation10)
  • •Ejection Fraction: ≥20 to ≤60%
  • •Symptom Status: NYHA II-IV (i.e., ambulatory)
  • •Treatment and compliance with optimal guideline directed medical therapy for heart failure for at least 1 month
  • •Surgical risk: Subject is eligible for cardiac surgery (specific risk score or comorbidities should demonstrate high risk features, as determined by the Heart Team)
  • •Completion of all qualifying diagnostic and functional tests and agrees to comply with study follow-up schedule

排除标准

  • •Patients with significant organic mitral valve pathology (e.g. myxomatous degeneration, mitral valve prolapse or flail leaflets)
  • •Myocardial infarction or any percutaneous cardiovascular intervention, cardiovascular surgery, or carotid surgery within 30 days
  • •Prior surgical, transcatheter, or percutaneous mitral valve intervention
  • •Untreated clinically significant coronary artery disease (CAD) requiring revascularization
  • •Hemodynamic instability: Hypotension (systolic pressure <90 mmHg) or requirement for inotropic support or mechanical hemodynamic support
  • •Any planned cardiac surgery or interventions within the next 6 months (including right heart procedures)
  • •NYHA class IV (i.e., non-ambulatory) or American College of Cardiology (ACC)/American Heart Association (AHA) Stage D heart failure
  • •Fixed pulmonary artery systolic pressure >70 mmHg
  • •Severe tricuspid regurgitation (per ASE guidelines and graded by the Echo Core Lab)
  • •Modified Rankin Scale ≥ 4 disability
  • •Hypertrophic cardiomyopathy, restrictive cardiomyopathy, constrictive pericarditis, or any other structural heart disease causing heart failure other than dilated cardiomyopathy of either ischemic or non-ischemic etiology.
  • •Anatomical pathology/constraints preventing appropriate access/implant of the AccuCinch® Ventricular Restoration System (e.g., femoral arteries will not support a 20F system)
  • •Renal insufficiency (i.e., eGFR of <30ml/min/1.73m2; Stage 4 or 5 CKD)
  • •Moderate or severe aortic valve stenosis or regurgitation or aortic valve prosthesis
  • •Fluoroscopic or echocardiographic evidence of severe aortic arch calcification, mobile aortic atheroma, intracardiac mass, thrombus or vegetation
  • •Active bacterial endocarditis

研究组 & 干预措施

AccuCinch® Ventricular Restoration System

Experimental

干预措施: Mitral valve repair (Device)

结局指标

主要结局

30-Day Safety

时间窗: 30-day

Assess 30-day safety defined as device-related or procedure-related major adverse events (MAEs). MAE is a composite of death; myocardial infarction; emergent conversion to surgery; stroke; major cardiac structure complication; major vascular complication; and heart failure-related hospitalization.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (16)

Loading locations...

相似试验