跳至主要内容
临床试验/NCT03560167
NCT03560167已完成不适用

An Early Feasibility Study of the AccuCinch® Ventricular Restoration System in Patients With Prior Mitral Valve Intervention (PMVI) and Recurrent Mitral Regurgitation - The CorCinch-PMVI Study

Ancora Heart, Inc.19 个研究点 分布在 1 个国家目标入组 5 人开始时间: 2018年9月24日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
5
试验地点
19
主要终点
Safety measured by device-related or procedure-related major adverse events (MAEs)

研究概览

简要总结

This is a non-randomized, prospective, multi-center Early Feasibility Study of the AccuCinch® Ventricular Restoration System in Patients with Prior Mitral Valve Intervention (PMVI) and Recurrent Mitral Regurgitation.

详细描述

Device name changed from AccuCinch® Ventricular Repair System to AccuCinch® Ventricular Restoration System, FDA Approval Date August 14, 2020.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Study patient is at least 18-years old
  • •Severity of FMR: ≥ Moderate (i.e., ≥2+, according to Stone et al Clinical Trial Design Principles and Endpoint Definitions for Transcatheter Mitral Valve Repair and Replacement: Part 1: Clinical Trial Design Principles. A Consensus Document from the Mitral Valve Academic Research Consortium1; and 2003 ASE Guidelines for grading mitral regurgitation2)
  • •Patient has had a prior surgical or percutaneous mitral repair procedure >3 months prior to enrollment
  • •LV Ejection Fraction: ≥20 to ≤40%
  • •Symptom Status: NYHA II-IV (i.e., ambulatory)
  • •Prescribed appropriate guideline-directed medical therapy for heart failure for at least 3 months with stable doses of diuretics, beta-blockers and Angiotensin converting enzyme inhibitor (ACEi) or Angiotensin II Receptor Blockers (ARB) for 1 month (with stable defined as no greater than 100% increase of 50% decrease in medication doses). Treatment shall include CRT and/or ICD when indicated by guidelines.
  • •Able and willing to complete all qualifying diagnostic and functional tests and agrees to comply with study follow-up schedule

排除标准

  • •Patients with significant organic mitral valve pathology (e.g. myxomatous degeneration, mitral valve prolapse or flail leaflets)
  • •Myocardial infarction or any percutaneous cardiovascular intervention, cardiovascular surgery, or carotid surgery within 3 months
  • •Prior surgical, transcatheter, or percutaneous mitral valve replacement
  • •Untreated clinically significant coronary artery disease (CAD) requiring revascularization
  • •Hemodynamic instability: Hypotension (systolic pressure <90 mmHg) or requirement for inotropic support or mechanical hemodynamic support
  • •Any planned cardiac surgery or interventions within the next 6 months (including right heart procedures)
  • •NYHA class IV (i.e., non-ambulatory)
  • •Fixed pulmonary artery systolic pressure >70 mmHg
  • •Severe tricuspid regurgitation
  • •History of stroke within the prior 3 months or any prior stroke with Modified Rankin Scale ≥ 4 disability
  • •Hypertrophic cardiomyopathy, restrictive cardiomyopathy, constrictive pericarditis, or any other structural heart disease causing heart failure other than dilated cardiomyopathy of either ischemic or non-ischemic etiology
  • •Anatomical pathology or constraints preventing appropriate access/implant of the AccuCinch® Ventricular Repair System (e.g., femoral arteries will not support a 20F system)
  • •Renal insufficiency (i.e., eGFR of <30ml/min/1.73m2; Stage 4 or 5 CKD)
  • •Moderate or severe aortic valve stenosis or regurgitation or aortic valve prosthesis
  • •Fluoroscopic or echocardiographic evidence of severe aortic arch calcification, mobile aortic atheroma, intracardiac mass, thrombus or vegetation
  • •Active bacterial endocarditis
  • •Subjects in whom anticoagulation or antiplatelet therapy is contraindicated
  • •Known allergy to nitinol, polyester, or polyethylene
  • •Any prior true anaphylactic reaction to contrast agents; defined as known anaphylactoid or other non-anaphylactic allergic reactions to contrast agents that cannot be adequately pre-medicated prior to the index procedure.
  • •Life expectancy < 1 year due to non-cardiac conditions
  • •Currently participating in another interventional investigational study
  • •Implant or revision of any rhythm management device (CRT or CRT-D) prior 3 months or implantable cardioverter defibrillator within the prior 1 month
  • •Subjects on high dose steroids or immunosuppressant therapy
  • •Female subjects who are pregnant, of child bearing potential without a documented birth control method, or lactating

研究组 & 干预措施

AccuCinch® Ventricular Restoration System

Experimental

干预措施: AccuCinch® Ventricular Restoration System (Device)

结局指标

主要结局

Safety measured by device-related or procedure-related major adverse events (MAEs)

时间窗: 30-day

Device-related or procedure-related major adverse events (MAEs)

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (19)

Loading locations...

相似试验